Registration Dossier

Diss Factsheets

Administrative data

Description of key information

Key value for chemical safety assessment

Skin sensitisation

Endpoint conclusion
Endpoint conclusion:
no adverse effect observed (not sensitising)
Additional information:

In a delayed contact hypersensitivity study in Guinea pigs (Buehler technique), 10 Pirbright White Guinea pigs were induced with 12.5% w/v test substance. Erythema, edema or other signs of allergic reactions were not noted in any animal following challenge exposure. The test substance does not appear to be a sensitizer in the guinea pig.


Migrated from Short description of key information:
The test material is not a skin sensitizer.

Respiratory sensitisation

Endpoint conclusion
Additional information:

No data on respiratory irritation are available for the test material.

Justification for classification or non-classification

In accordance to Directive 67/548/EEC and EU CLP (Regulation (EC) No. 1272/2008), this substance does not meet the criteria for classification as a skin sensitizer.