Registration Dossier

Diss Factsheets

Physical & Chemical properties

Water solubility

Currently viewing:

Administrative data

Link to relevant study record(s)

Description of key information

< 4.0 µg/L at 20°C at pH 7.5

Key value for chemical safety assessment

Additional information

The determination was performed by Column Elution Method according to OECD Guideline 105. The quantitative analysis of the test item in water was measured by an ultra performance liquid chromatographic method with tandem mass spectrometric detection (UPLC-MS/MS).

The limit of quantification (LOQ) was assessed at 5µg/Lin water.