Registration Dossier

Administrative data

Endpoint:
relative self-ignition temperature (solids)
Type of information:
experimental study
Adequacy of study:
key study
Study period:
from November 10th, 1988 to January 13th, 1989.
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
other: GLP study performed according to the Test Guideline A.16 of the EEC Directive 84/449/EEC

Data source

Reference
Reference Type:
study report
Title:
Unnamed
Year:
1989
Report date:
1989

Materials and methods

Test guideline
Qualifier:
according to guideline
Guideline:
EU Method A.16 (Relative Self-Ignition Temperature for Solids)
GLP compliance:
yes

Test material

Reference
Name:
Unnamed
Type:
Constituent
Details on test material:
Name : AF-366
Appearance : white powder
Purity : 97.5 %

Results and discussion

Relative self-ignition temperature (solids)
Relative self-ignition temperature:
> 650 °C
Remarks on result:
other:
Remarks:
at atm. press. of ca.1.0 atm

Applicant's summary and conclusion

Conclusions:
AF—366 is not autoflammable.