Registration Dossier

Diss Factsheets

Environmental fate & pathways

Biodegradation in water: screening tests

Currently viewing:

Administrative data

Endpoint:
biodegradation in water: ready biodegradability
Type of information:
experimental study
Adequacy of study:
key study

Data source

Reference
Reference Type:
study report
Title:
Unnamed
Report date:
2000

Materials and methods

Test guideline
Qualifier:
according to guideline
Guideline:
OECD Guideline 301 F (Ready Biodegradability: Manometric Respirometry Test)

Test material

Study design

Oxygen conditions:
aerobic
Inoculum or test system:
sewage, domestic, non-adapted
Duration of test (contact time):
28 d
Initial test substance concentration
Initial conc.:
100 mg/L
Based on:
test mat.

Results and discussion

% Degradation
Parameter:
% degradation (O2 consumption)
Value:
28
Sampling time:
28 d

Applicant's summary and conclusion

Validity criteria fulfilled:
yes