Registration Dossier

Diss Factsheets

Physical & Chemical properties

Auto flammability

Currently viewing:

Administrative data

Endpoint:
auto-flammability
Type of information:
experimental study
Adequacy of study:
key study
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
other: Guideline study

Data source

Reference
Reference Type:
study report
Title:
Unnamed
Report date:
1999

Materials and methods

Test guideline
Qualifier:
according to guideline
Guideline:
other: A.13
Deviations:
no
Principles of method if other than guideline:
A13: Pyriphoric properties of solids and liquids 1.6.2.b
GLP compliance:
yes (incl. QA statement)

Test material

Reference
Name:
Unnamed
Type:
Constituent
Test material form:
other: liquid
Details on test material:
Batch 10466 QB
Purity 96.3 %

Results and discussion

Auto-ignition temperature (liquids / gases)
Remarks on result:
other: no flammability was observed
Relative self-ignition temperature (solids)
Remarks on result:
other: no flammability was observed

Any other information on results incl. tables

test

ignition [Yes/No]

    porcelain cup filled with diatomaceous earth

1.

No

    approx. 5 cm³ test substance

2.

No

3.

No

4.

No

5.

No

6.

No

x       Liquids / EC test guideline A.13.1.6.2.b:

test

ignition [Yes/No]

    dry filter paper, 0.5 ml test substance

1.

No

    necessary, if no ignition with diatomaceous

2.

No

    earth

3.

No

Applicant's summary and conclusion

Conclusions:
The results of the six tests with diatomaceous earth and the tests with filter paper
were negative, i. e. no flammability was observed.

Categories Display