Registration Dossier

Physical & Chemical properties

Particle size distribution (Granulometry)

Currently viewing:

Administrative data

Link to relevant study record(s)

Description of key information

Using the laser diffraction test the following particle size distribution was determined:
D10 = 11.34 µm, D50 = 182.54 µm, D90 = 597.17 µm.
The volume fraction of particles with a particle diameter lower than 2 µm was ca. 0.05 %.
The volume fraction of particles with a particle diameter lower than 10 µm was ca. 9.18 %.

Additional information

The particle size distribution was determined in a GLP guideline study according to OECD 110. Measurement was performed by the laser diffraction method.