Registration Dossier

Data platform availability banner - registered substances factsheets

Please be aware that this old REACH registration data factsheet is no longer maintained; it remains frozen as of 19th May 2023.

The new ECHA CHEM database has been released by ECHA, and it now contains all REACH registration data. There are more details on the transition of ECHA's published data to ECHA CHEM here.

Diss Factsheets

Physical & Chemical properties

Viscosity

Currently viewing:

Administrative data

Link to relevant study record(s)

Reference
Endpoint:
viscosity
Type of information:
experimental study
Adequacy of study:
key study
Study period:
2017-11-09
Reliability:
2 (reliable with restrictions)
Rationale for reliability incl. deficiencies:
guideline study with acceptable restrictions
Remarks:
The study was conducted in accordance with relevant test method but not in compliance with GLP
Qualifier:
according to guideline
Guideline:
DIN 51562 Part 1 (Viscometry - Measurement of kinematic viscosity by means of the Ubbelohde viscometer - Part 1: Viscometer specification and measurement procedure)
GLP compliance:
no
Other quality assurance:
ISO/IEC 17025 (General requirements for the competence of testing and calibration laboratories)
Remarks:
ISO 9001:2008
Type of method:
capillary viscometer (static)
Key result
Temp.:
20°C
Parameter:
kinematic viscosity (in mm²/s)
Value:
1.77

Test: 1


 Capillary tube: 0a  


Correction factor: 0.005135






















Measured time [s]



Measured time [s]



Measured time [s]



Measured time [s]



Measured time [s]



Mean value [s]



344



343



343



343



343



343.2



 


Calculation: time (mean value) x correction factor = viscosity = 1.7623 mm2/s


 


Test: 2


 Capillary tube: I  


Correction factor: 0.009860






















Measured time [s]



Measured time [s]



Measured time [s]



Measured time [s]



Measured time [s]



Mean value [s]



180



179



179



180



179



179.4



 


Calculation: time (mean value) x correction factor = viscosity = 1.7689 mm2/s


 

Conclusions:
A kinematic viscosity value of 1.77 mm2/s at 20°C was determined for the substance using a relevant test method. The result is considered to be reliable.

Description of key information

Viscosity: 1.77 mm2/s at 20°C (DIN 51562)

Key value for chemical safety assessment

Viscosity:
1.77 mm²/s (static)
at the temperature of:
20 °C

Additional information

A kinematic viscosity value of 1.77 mm2/s at 20°C was determined for the substance using a capillary viscometer (static) method and in compliance with a known quality system (ISO 9001:2008). The result is considered to be reliable.


 


The key study is supported by a predicted kinematic viscosity value of 1.8 mm2/s at 20°C which was determined for the substance using a validated QSAR estimation method.


 


In an available secondary source to which reliability could not be assigned, a dynamic viscosity value of 2 mPa.s at 20°C was reported for the substance.