Registration Dossier

Diss Factsheets

Administrative data

Endpoint:
flash point
Type of information:
experimental study
Adequacy of study:
key study
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
other: Meets the criteria for classification as Reliable without restriction according to Klimisch et al (1997)

Data source

Reference
Reference Type:
study report
Title:
Unnamed
Year:
1997

Materials and methods

Test guideline
Qualifier:
according to guideline
Guideline:
ISO No., other: 92/69/EEC, A9
GLP compliance:
yes
Type of method:
closed cup

Test material

Reference
Name:
Unnamed
Type:
Constituent

Results and discussion

Flash point
Flash point:
ca. 58 °C
Atm. press.:
ca. 101 kPa

Any other information on results incl. tables

The non-equilibrium method gave a result of 56 Deg C and so the test was repeated using an equilibrium method.

Applicant's summary and conclusion