Registration Dossier

Administrative data

Endpoint:
vapour pressure
Type of information:
experimental study
Adequacy of study:
key study
Reliability:
1 (reliable without restriction)
Cross-reference
Reason / purpose:
reference to other study

Data source

Reference
Reference Type:
study report
Title:
Unnamed
Year:
2007
Report Date:
2007

Materials and methods

Test guideline
Qualifier:
according to
Guideline:
EU Method A.4 (Vapour Pressure)
Version / remarks:
92/69/EEC, A4 (Vapour Pressure balance)
Deviations:
no
GLP compliance:
yes
Type of method:
effusion method: vapour pressure balance

Test material

Reference
Name:
Unnamed
Type:
Constituent

Results and discussion

Vapour pressure
Temp.:
25 °C
Vapour pressure:
0.06 Pa
Remarks on result:
other: First vapour pressure

Applicant's summary and conclusion

Conclusions:
The vapour pressure of Trimofix O was found to be 0.06 Pa at 25 deg.C.
Executive summary:

The vapour pressure of Trimofix O was found to be 0.06 Pa at 25 deg.C.