Registration Dossier

Data platform availability banner - registered substances factsheets

Please be aware that this old REACH registration data factsheet is no longer maintained; it remains frozen as of 19th May 2023.

The new ECHA CHEM database has been released by ECHA, and it now contains all REACH registration data. There are more details on the transition of ECHA's published data to ECHA CHEM here.

Diss Factsheets

Physical & Chemical properties

Particle size distribution (Granulometry)

Administrative data

Endpoint:
particle size distribution (granulometry)
Type of information:
experimental study
Adequacy of study:
key study
Study period:
2010
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
other: The study performed in accordance with Guideline

Data source

Reference
Reference Type:
study report
Title:
Unnamed
Year:
2010
Report date:
2010

Materials and methods

Test guideline
Qualifier:
according to guideline
Guideline:
OECD Guideline 110 (Particle Size Distribution / Fibre Length and Diameter Distributions)
Version / remarks:
and EUR 20268 EN (2002), Draft
GLP compliance:
no
Type of method:
Laser scattering/diffraction
Type of distribution:
volumetric distribution

Test material

Constituent 1
Chemical structure
Reference substance name:
2,2,6,6-tetramethylpiperidin-4-ol
EC Number:
219-291-2
EC Name:
2,2,6,6-tetramethylpiperidin-4-ol
Cas Number:
2403-88-5
Molecular formula:
C9H19NO
IUPAC Name:
2,2,6,6-tetramethylpiperidin-4-ol
Details on test material:
- Substance type: organic
- Physical state: solid
- Lot/batch No.: 00213CN9

Results and discussion

Particle sizeopen allclose all
Key result
Percentile:
D50
Mean:
620 µm
Remarks on result:
other: no data on St. dev.
Key result
Percentile:
D90
Mean:
1 546 µm
Remarks on result:
other: no data on St. dev.
Key result
Percentile:
D10
Mean:
333 µm
Remarks on result:
other: no data on St. dev

Any other information on results incl. tables

Standard deviation not reported.


Mean value of 3 measurements

Applicant's summary and conclusion

Conclusions:
The particle size distribution of test substance was determined to be MMD=620µm