Registration Dossier
Registration Dossier
Data platform availability banner - registered substances factsheets
Please be aware that this old REACH registration data factsheet is no longer maintained; it remains frozen as of 19th May 2023.
The new ECHA CHEM database has been released by ECHA, and it now contains all REACH registration data. There are more details on the transition of ECHA's published data to ECHA CHEM here.
Diss Factsheets
Use of this information is subject to copyright laws and may require the permission of the owner of the information, as described in the ECHA Legal Notice.
EC number: 219-784-2 | CAS number: 2530-83-8
- Life Cycle description
- Uses advised against
- Endpoint summary
- Appearance / physical state / colour
- Melting point / freezing point
- Boiling point
- Density
- Particle size distribution (Granulometry)
- Vapour pressure
- Partition coefficient
- Water solubility
- Solubility in organic solvents / fat solubility
- Surface tension
- Flash point
- Auto flammability
- Flammability
- Explosiveness
- Oxidising properties
- Oxidation reduction potential
- Stability in organic solvents and identity of relevant degradation products
- Storage stability and reactivity towards container material
- Stability: thermal, sunlight, metals
- pH
- Dissociation constant
- Viscosity
- Additional physico-chemical information
- Additional physico-chemical properties of nanomaterials
- Nanomaterial agglomeration / aggregation
- Nanomaterial crystalline phase
- Nanomaterial crystallite and grain size
- Nanomaterial aspect ratio / shape
- Nanomaterial specific surface area
- Nanomaterial Zeta potential
- Nanomaterial surface chemistry
- Nanomaterial dustiness
- Nanomaterial porosity
- Nanomaterial pour density
- Nanomaterial photocatalytic activity
- Nanomaterial radical formation potential
- Nanomaterial catalytic activity
- Endpoint summary
- Stability
- Biodegradation
- Bioaccumulation
- Transport and distribution
- Environmental data
- Additional information on environmental fate and behaviour
- Ecotoxicological Summary
- Aquatic toxicity
- Endpoint summary
- Short-term toxicity to fish
- Long-term toxicity to fish
- Short-term toxicity to aquatic invertebrates
- Long-term toxicity to aquatic invertebrates
- Toxicity to aquatic algae and cyanobacteria
- Toxicity to aquatic plants other than algae
- Toxicity to microorganisms
- Endocrine disrupter testing in aquatic vertebrates – in vivo
- Toxicity to other aquatic organisms
- Sediment toxicity
- Terrestrial toxicity
- Biological effects monitoring
- Biotransformation and kinetics
- Additional ecotoxological information
- Toxicological Summary
- Toxicokinetics, metabolism and distribution
- Acute Toxicity
- Irritation / corrosion
- Sensitisation
- Repeated dose toxicity
- Genetic toxicity
- Carcinogenicity
- Toxicity to reproduction
- Specific investigations
- Exposure related observations in humans
- Toxic effects on livestock and pets
- Additional toxicological data
Explosiveness
Administrative data
Link to relevant study record(s)
- Endpoint:
- explosive properties of explosives
- Type of information:
- experimental study
- Adequacy of study:
- key study
- Reliability:
- 1 (reliable without restriction)
- Rationale for reliability incl. deficiencies:
- guideline study
- Qualifier:
- according to guideline
- Guideline:
- EU Method A.14 (Explosive properties)
- Version / remarks:
- according to the EEC regulation No. 440/2008
- GLP compliance:
- no
- Other quality assurance:
- ISO/IEC 17025 (General requirements for the competence of testing and calibration laboratories)
- Key result
- Parameter:
- sensitiveness to impact: impact energy (J)
- Remarks on result:
- not sensitive to impact using an impact energy of 40 J
- Key result
- Parameter:
- thermal sensitivity - Koenen test: diameter of the orifice plate
- Remarks:
- 6 mm orifice
- Value:
- 6
- Number of fragments:
- 0
- Remarks on result:
- not thermal sensitive if heated under defined confinement
- Key result
- Parameter:
- thermal sensitivity - Koenen test: diameter of the orifice plate
- Remarks:
- 2 mm orifice
- Value:
- 2
- Number of fragments:
- 0
- Remarks on result:
- not thermal sensitive if heated under defined confinement
- Interpretation of results:
- GHS criteria not met
- Conclusions:
- The substance was reported not to be an explosive hazard, determined in a reliable study conducted according to an appropriate test protocol. No further details are available.
Reference
Mechanical shock sensitivity
None of the six single tests with an impact energy of 40 J showed any sparking or exploding. Therefore the test series using impact energies of 7.5 J were not necessary. No impact sensitivity of the test item was observed.
Thermal sensitivity
Using the 6 mm orifice after 73-75 s the start of a reaction was observed in the single tests (yellow coloured flame of about 1.5 m height above the tube and escaping of the test substance). The reaction lasted 65-67 s. After about 170 s the bottom of the steel tubes became glowing red. The burners were turned off after 5 minutes. After cooling down it was observed that all the tubes were unchanged.
Using the 2 mm orifice after 67-69 s the start of a reaction was observed in the single tests (yellow coloured flame of about 1.5 m height above the tube and escaping of the test substance connected with a noisy sound). The reaction lasted 65-66 s. After about 170 s the bottom of the steel tubes became glowing red. The burners were turned off after 5 minutes. After cooling down it was observed that all the tubes were unchanged.
Description of key information
Explosiveness: Not explosive
Key value for chemical safety assessment
- Explosiveness:
- non explosive
Additional information
The substance was determined not to be explosive in a reliable study conducted according to an appropriate test protocol (EU Method A.14), and in compliance with a known quality system (ISO 17025).
Justification for classification or non-classification
The substance is not classified for explosivity on the basis of measured explosivity study in accordance with EU Method A.14.
Information on Registered Substances comes from registration dossiers which have been assigned a registration number. The assignment of a registration number does however not guarantee that the information in the dossier is correct or that the dossier is compliant with Regulation (EC) No 1907/2006 (the REACH Regulation). This information has not been reviewed or verified by the Agency or any other authority. The content is subject to change without prior notice.