Registration Dossier

Data platform availability banner - registered substances factsheets

Please be aware that this old REACH registration data factsheet is no longer maintained; it remains frozen as of 19th May 2023.

The new ECHA CHEM database has been released by ECHA, and it now contains all REACH registration data. There are more details on the transition of ECHA's published data to ECHA CHEM here.

Diss Factsheets

Physical & Chemical properties

Viscosity

Currently viewing:

Administrative data

Link to relevant study record(s)

Reference
Endpoint:
viscosity
Type of information:
experimental study
Adequacy of study:
key study
Study period:
2010
Reliability:
2 (reliable with restrictions)
Rationale for reliability incl. deficiencies:
comparable to guideline study
Remarks:
Conducted according to a standard method, with a commercial apparatus, but not GLP
Qualifier:
according to guideline
Guideline:
other: ASTM D-7042-04
Qualifier:
equivalent or similar to guideline
Guideline:
other: ISO 3104
Qualifier:
equivalent or similar to guideline
Guideline:
OECD Test Guideline 114 (Viscosity of Liquids)
Principles of method if other than guideline:
The SVM 3000 Stabinger Viscometer is being used (supplier: Anton Paar), see: http://www.anton-paar.com/Kinematic-Viscosity-SVM-3000-Stabinger-Viscometer/Viscometers/60_Corporate_en?product_id=33#Features
GLP compliance:
no
Type of method:
capillary viscometer (static)
Key result
Temp.:
20°C
Parameter:
dynamic viscosity (in mPa s)
Value:
1 800
Conclusions:
The substance is manufactured in different viscosities

Description of key information

The substance is manufactured in different viscosities, from just below 100 mPa*s, up to a viscosity of 9 Pa*s. The viscosity of the quality used for the studies is in almost all cases approximately 1.8 Pa*s (this information is provided in the confidential section of the description of test material). Most of the substance is manufactured with this viscosity.

Key value for chemical safety assessment

Viscosity:
1 800 mPa · s (dynamic)
at the temperature of:
20 °C

Additional information

Company data. The manufacturers measure the viscosity regularly. All reported dynamic viscosities are measured at 20 degrees Celsius.