Registration Dossier
Registration Dossier
Diss Factsheets
Use of this information is subject to copyright laws and may require the permission of the owner of the information, as described in the ECHA Legal Notice.
EC number: 270-695-5 | CAS number: 68476-55-1
- Life Cycle description
- Uses advised against
- Endpoint summary
- Appearance / physical state / colour
- Melting point / freezing point
- Boiling point
- Density
- Particle size distribution (Granulometry)
- Vapour pressure
- Partition coefficient
- Water solubility
- Solubility in organic solvents / fat solubility
- Surface tension
- Flash point
- Auto flammability
- Flammability
- Explosiveness
- Oxidising properties
- Oxidation reduction potential
- Stability in organic solvents and identity of relevant degradation products
- Storage stability and reactivity towards container material
- Stability: thermal, sunlight, metals
- pH
- Dissociation constant
- Viscosity
- Additional physico-chemical information
- Additional physico-chemical properties of nanomaterials
- Nanomaterial agglomeration / aggregation
- Nanomaterial crystalline phase
- Nanomaterial crystallite and grain size
- Nanomaterial aspect ratio / shape
- Nanomaterial specific surface area
- Nanomaterial Zeta potential
- Nanomaterial surface chemistry
- Nanomaterial dustiness
- Nanomaterial porosity
- Nanomaterial pour density
- Nanomaterial photocatalytic activity
- Nanomaterial radical formation potential
- Nanomaterial catalytic activity
- Endpoint summary
- Stability
- Biodegradation
- Bioaccumulation
- Transport and distribution
- Environmental data
- Additional information on environmental fate and behaviour
- Ecotoxicological Summary
- Aquatic toxicity
- Endpoint summary
- Short-term toxicity to fish
- Long-term toxicity to fish
- Short-term toxicity to aquatic invertebrates
- Long-term toxicity to aquatic invertebrates
- Toxicity to aquatic algae and cyanobacteria
- Toxicity to aquatic plants other than algae
- Toxicity to microorganisms
- Endocrine disrupter testing in aquatic vertebrates – in vivo
- Toxicity to other aquatic organisms
- Sediment toxicity
- Terrestrial toxicity
- Biological effects monitoring
- Biotransformation and kinetics
- Additional ecotoxological information
- Toxicological Summary
- Toxicokinetics, metabolism and distribution
- Acute Toxicity
- Irritation / corrosion
- Sensitisation
- Repeated dose toxicity
- Genetic toxicity
- Carcinogenicity
- Toxicity to reproduction
- Specific investigations
- Exposure related observations in humans
- Toxic effects on livestock and pets
- Additional toxicological data

Viscosity
Administrative data
Link to relevant study record(s)
- Endpoint:
- viscosity
- Type of information:
- experimental study
- Adequacy of study:
- key study
- Reliability:
- 1 (reliable without restriction)
- Rationale for reliability incl. deficiencies:
- test procedure in accordance with national standard methods
- Qualifier:
- equivalent or similar to guideline
- Guideline:
- ISO 3104 (Petroleum products - Transparent and opaque liquids - Determination of kinematic viscosity and calculation of dynamic viscosity)
- Version / remarks:
- IP 71 method followed
- GLP compliance:
- no
- Type of method:
- capillary viscometer (static)
- Key result
- Temp.:
- 40°C
- Parameter:
- kinematic viscosity (in mm²/s)
- Value:
- 0.488
- Conclusions:
- The kinematic viscosity of this substance is 0.4879 mm2/s at 40ºC.
- Executive summary:
The kinematic viscosity of this substance was determined following the ISO 3104 guideline (method IP71) and was found to be 0.4879 mm2/s at 40ºC.
- Endpoint:
- viscosity
- Type of information:
- experimental study
- Adequacy of study:
- key study
- Reliability:
- 1 (reliable without restriction)
- Rationale for reliability incl. deficiencies:
- test procedure in accordance with national standard methods
- Qualifier:
- equivalent or similar to guideline
- Guideline:
- ISO 3104 (Petroleum products - Transparent and opaque liquids - Determination of kinematic viscosity and calculation of dynamic viscosity)
- Version / remarks:
- IP 71 method followed
- GLP compliance:
- no
- Type of method:
- capillary viscometer (static)
- Key result
- Temp.:
- 40°C
- Parameter:
- kinematic viscosity (in mm²/s)
- Value:
- 0.575
- Conclusions:
- The kinematic viscosity of this substance is 0.5745 mm2/s at 40ºC
- Executive summary:
The kinematic viscosity of this substance was determined following the ISO 3104 guideline (method IP71) and was found to be 0.5745 mm2/s at 40ºC
- Endpoint:
- viscosity
- Type of information:
- experimental study
- Adequacy of study:
- key study
- Reliability:
- 1 (reliable without restriction)
- Rationale for reliability incl. deficiencies:
- test procedure in accordance with national standard methods
- Qualifier:
- equivalent or similar to guideline
- Guideline:
- ISO 3104 (Petroleum products - Transparent and opaque liquids - Determination of kinematic viscosity and calculation of dynamic viscosity)
- Version / remarks:
- IP 71 method followed
- GLP compliance:
- no
- Type of method:
- capillary viscometer (static)
- Key result
- Temp.:
- 40°C
- Parameter:
- kinematic viscosity (in mm²/s)
- Value:
- 0.507
- Conclusions:
- : The kinematic viscosity of this substance is 0.5067 mm2/s at 40ºC
- Executive summary:
The kinematic viscosity of this substance was determined following the ISO 3104 guideline (method IP71) and was found to be 0.5067 mm2/s at 40ºC
- Endpoint:
- viscosity
- Type of information:
- experimental study
- Adequacy of study:
- key study
- Reliability:
- 1 (reliable without restriction)
- Rationale for reliability incl. deficiencies:
- test procedure in accordance with national standard methods
- Qualifier:
- equivalent or similar to guideline
- Guideline:
- ISO 3104 (Petroleum products - Transparent and opaque liquids - Determination of kinematic viscosity and calculation of dynamic viscosity)
- Version / remarks:
- IP 71 method followed
- GLP compliance:
- no
- Type of method:
- capillary viscometer (static)
- Key result
- Temp.:
- 40°C
- Parameter:
- kinematic viscosity (in mm²/s)
- Value:
- 0.556
- Conclusions:
- The kinematic viscosity of this substance is 0.556 mm2/s at 40ºC
- Executive summary:
The kinematic viscosity of this substance was determined following the ISO 3104 guideline (method IP71) and was found to be 0.556 mm2/s at 40ºC
- Endpoint:
- viscosity
- Type of information:
- experimental study
- Adequacy of study:
- key study
- Study period:
- 08/12/2008 - 08/04/2009
- Reliability:
- 1 (reliable without restriction)
- Rationale for reliability incl. deficiencies:
- other: GLP compliant, guideline study, experimental study. No restrictions, fully adequate for assessment
- Qualifier:
- according to guideline
- Guideline:
- OECD Test Guideline 114 (Viscosity of Liquids)
- Deviations:
- no
- GLP compliance:
- yes
- Type of method:
- capillary viscometer (static)
- Temp.:
- 20°C
- Parameter:
- kinematic viscosity (in mm²/s)
- Value:
- 0.61
- Remarks on result:
- other: kinematic viscosity
- Temp.:
- 40°C
- Parameter:
- kinematic viscosity (in mm²/s)
- Value:
- 0.5
- Remarks on result:
- other: kinematic viscosity
- Temp.:
- 20°C
- Parameter:
- dynamic viscosity (in mPa s)
- Value:
- 0.44
- Remarks on result:
- other: dynamic viscosity
- Temp.:
- 40°C
- Parameter:
- dynamic viscosity (in mPa s)
- Value:
- 0.35
- Remarks on result:
- other: dynamic viscosity
- Conclusions:
- The kinematic viscosity of the substance at 20 °C is 0.61 mm2/s (static) and at 40 °C is 0.50 mm2/s (static). The dynamic viscosity for the substance at 20 °C is 0.44 mPa.s (dynamic) and at 40 °C is 0.35 mPa.s (dynamic).
- Executive summary:
The study is GLP compliant and carried out to a standard guideline, therefore the data is considered reliable. The kinematic viscosity of the substance at 20 °C is 0.61 mm2/s (static) and at 40 °C is 0.50 mm2/s (static). The dynamic viscosity for the substance at 20 °C is 0.44 mPa.s (dynamic) and at 40 °C is 0.35 mPa.s (dynamic).
- Endpoint:
- viscosity
- Type of information:
- experimental study
- Adequacy of study:
- key study
- Study period:
- 06/06/2007 - 16/10/2007
- Reliability:
- 1 (reliable without restriction)
- Rationale for reliability incl. deficiencies:
- other: GLP compliant, guideline study, available as unpublished report, no restrictions fully adequate for assessment
- Qualifier:
- according to guideline
- Guideline:
- OECD Test Guideline 114 (Viscosity of Liquids)
- Deviations:
- no
- GLP compliance:
- yes
- Type of method:
- other: Kinematic and dynamic
- Temp.:
- 20°C
- Parameter:
- kinematic viscosity (in mm²/s)
- Value:
- 0.55
- Temp.:
- 40°C
- Parameter:
- kinematic viscosity (in mm²/s)
- Value:
- 0.47
- Temp.:
- 20°C
- Parameter:
- dynamic viscosity (in mPa s)
- Value:
- 0.38
- Temp.:
- 40°C
- Parameter:
- dynamic viscosity (in mPa s)
- Value:
- 0.32
- Conclusions:
- The kinematic viscosity of 68476-55-1 at 20 °C is 0.55 mm2/s (static) and at 40 °C is 0.47 mm2/s (static). The dynamic viscosity for the substance at 20 °C is 0.38 mPa.s (dynamic) and at 40 °C is 0.32 mPa.s (dynamic).
- Executive summary:
This study was conducted to a standard guideline and according to GLP and so is considered fully reliable for use as a key study. The kinematic viscosity of 68476-55-1 at 20 °C is 0.55 mm2/s (static) and at 40 °C is 0.47 mm2/s (static). The dynamic viscosity for the substance at 20 °C is 0.38 mPa.s (dynamic) and at 40 °C is 0.32 mPa.s (dynamic).
- Endpoint:
- viscosity
- Type of information:
- experimental study
- Adequacy of study:
- key study
- Study period:
- 23/10/2007 - 04/03/2008
- Reliability:
- 1 (reliable without restriction)
- Rationale for reliability incl. deficiencies:
- other: GLP compliant,guideline study, available as unpublished report, no restrictions fully adequate for assessment
- Qualifier:
- according to guideline
- Guideline:
- OECD Test Guideline 114 (Viscosity of Liquids)
- Deviations:
- no
- GLP compliance:
- yes
- Type of method:
- other: Kinematic and dynamic
- Temp.:
- 20°C
- Parameter:
- kinematic viscosity (in mm²/s)
- Value:
- 0.64
- Temp.:
- 40°C
- Parameter:
- kinematic viscosity (in mm²/s)
- Value:
- 0.53
- Temp.:
- 20°C
- Parameter:
- dynamic viscosity (in mPa s)
- Value:
- 0.47
- Temp.:
- 40°C
- Parameter:
- dynamic viscosity (in mPa s)
- Value:
- 0.38
- Conclusions:
- The kinematic viscosity of the substance at 20 °C is 0.64 mm2/s (static) and at 40 °C is 0.53 mm2/s (static). The dynamic viscosity for the substance at 20 °C is 0.47 mPa.s (dynamic) and at 40 °C is 0.38 mPa.s (dynamic).
- Executive summary:
This study was conducted to a standard guideline and according to GLP and so is considered fully reliable for use as a key study. The kinematic viscosity of the substance at 20 °C is 0.64 mm2/s (static) and at 40 °C is 0.53 mm2/s (static). The dynamic viscosity for the substance at 20 °C is 0.47 mPa.s (dynamic) and at 40 °C is 0.38 mPa.s (dynamic).
Referenceopen allclose all
Description of key information
The kinematic and dynamic viscosity of three streams in this category range from 0.55-0.64 mm2/s (static) at 20°C, 0.47-0.53 mm2/s (static) at 40°C, 0.38-0.47 mPa/s (dynamic) at 20°C and 0.32-0.38 mPa/s (dynamic) at 40°C.
Key value for chemical safety assessment
- Viscosity:
- 0.6 mm²/s (static)
- at the temperature of:
- 20 °C
Additional information
Data from GKA competence centre analytics (2008, 2008 & 2009) are available for three of the streams in this category (64742-49-0: 0.61 mm²/s (static) and 0.44 mPa.s (dynamic) at 20°C and 0.50 mm²/s (static) and 0.35 mPa.s (dynamic) at 40°C, 92128-65-9: 0.64 mm²/s (static) and 0.47 mPa.s (dynamic) at 20°C and 0.53 mm²/s (static) and 0.38 mPa.s (dynamic) at 40°C, 68476-55-1: 0.55 mm²/s (static) and 0.38 mPa.s (dynamic) at 20°C and 0.47 mm²/s (static) at 20°C and 0.32 mPa.s (dynamic) at 40°C). These data will be read across to all category members.
New data areavilable for 4 streams in this category from Intertek (2018):
EC# 295-762-6: 0.556 mm2/s at 40ºC
EC# 270-695-5: 0.5067 mm2/s at 40ºC
EC# 265-151-9: 0.5745 mm2/s at 40ºC
EC#
265-086-6: 0.4879 mm2/s at 40ºC.
The mean of the kinematic viscosity values for the category is 0.60 mm²/s (static) at 20°C and this has been used to complete the 'key value for chemical safety assessment'.
Information on Registered Substances comes from registration dossiers which have been assigned a registration number. The assignment of a registration number does however not guarantee that the information in the dossier is correct or that the dossier is compliant with Regulation (EC) No 1907/2006 (the REACH Regulation). This information has not been reviewed or verified by the Agency or any other authority. The content is subject to change without prior notice.
Reproduction or further distribution of this information may be subject to copyright protection. Use of the information without obtaining the permission from the owner(s) of the respective information might violate the rights of the owner.