Physical & Chemical properties

Boiling point

Currently viewing:

Administrative data

Link to relevant study record(s)

Referenceopen allclose all

Endpoint:
boiling point
Type of information:
experimental study
Adequacy of study:
key study
Reliability:
2 (reliable with restrictions)
Rationale for reliability incl. deficiencies:
other: GLP status not known, guideline study, available as an unpublished report, reliable with restrictions
Qualifier:
according to guideline
Guideline:
other: EN ISO 3405
Deviations:
no
Qualifier:
according to guideline
Guideline:
other: ASTM D 86
Deviations:
no
GLP compliance:
not specified
Type of method:
other: Not specified
Boiling pt.:
> 25 - < 48 °C
Atm. press.:
1 013 hPa
Decomposition:
no
Conclusions:
The boiling point of substance 102110-14-5 is 25 - 48 °C.
Executive summary:

This is a guideline study and is considered reliable and suitable for use for this endpoint. The boiling point of substance 102110-14-5 is 25 - 48 °C.

Endpoint:
boiling point
Type of information:
calculation (if not (Q)SAR)
Remarks:
Migrated phrase: estimated by calculation
Adequacy of study:
key study
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
other: GLP status not known, guideline study, experimental study. No restrictions, fully adequate for assessment
Qualifier:
according to guideline
Guideline:
other: OECD 104
Principles of method if other than guideline:
Normal boiling temperature was deducted from vapour pressure data by static method according to OECD guideline 104
GLP compliance:
not specified
Type of method:
other: calculated
Boiling pt.:
101.9 °C
Atm. press.:
1 013.25 Pa
Decomposition:
no
Conclusions:
The boiling point was calculated as 101.9°C at 1013.25 hPa.
Executive summary:

Although the GLP status of this study is not known, it follows a standard guideline and is considered reliable for this endpoint. The boiling point was calculated as 101.9°C at 1013.25 hPa.

Endpoint:
boiling point
Type of information:
calculation (if not (Q)SAR)
Remarks:
Migrated phrase: estimated by calculation
Adequacy of study:
key study
Study period:
08/12/2008 - 08/04/2009
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
other: GLP compliant, guideline study, experimental study. No restrictions, fully adequate for assessment
Qualifier:
according to guideline
Guideline:
other: OECD 104
Principles of method if other than guideline:
As this is a mixture of substances of different volatility, the dynamic method according to OECD guideline 103 is not suitable. The normal boiling temperature was calculated from vapour pressure data by static method according to OECD guideline 104.
GLP compliance:
yes
Type of method:
other: calculated
Boiling pt.:
71.27 °C
Atm. press.:
1 013.25 hPa
Decomposition:
no
Conclusions:
The normal boiling temperature of the substance is 71.27 °C at 1013.25 hPa.
Executive summary:

The study is GLP compliant and was carried out to a standard guideline, therefore the data is considered reliable. The normal boiling temperature of the substance is 71.27 °C at 1013.25 hPa.

Endpoint:
boiling point
Type of information:
experimental study
Adequacy of study:
key study
Study period:
06/06/2007 - 16/10/2007
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
other: GLP compliant, guideline study, available as unpublished report, no restrictions fully adequate for assessment
Qualifier:
according to guideline
Guideline:
other: OECD Guideline 104
Deviations:
no
GLP compliance:
yes
Type of method:
dynamic method
Boiling pt.:
44.8 °C
Atm. press.:
1 013 hPa
Decomposition:
no

The normal boiling point was deduced from the vapour pressure data by interpolation

Conclusions:
The boiling point of 68476-55-1 is 44.8°C.
Executive summary:

This study was conducted to a standard guideline and according to GLP and so is considered fully reliable for use as a key study. The boiling point of 68476-55-1 is 44.8°C.

Endpoint:
boiling point
Type of information:
experimental study
Adequacy of study:
key study
Study period:
23/10/2007 - 04/03/2008
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
other: GLP compliant,guideline study, available as unpublished report, no restrictions, fully adequate for assessment
Qualifier:
according to guideline
Guideline:
other: OECD Test Guideline 104
Deviations:
no
GLP compliance:
yes
Type of method:
other: static
Boiling pt.:
73.4 °C
Atm. press.:
1 013.25 hPa
Decomposition:
no

The normal boiling point was deduced from the vapour pressure data by interpolation

Conclusions:
The boiling point of 92128-65-9 is 73.4°C.
Executive summary:

This study was conducted to a standard guideline and according to GLP and so is considered fully reliable for use as a key study. The boiling point of 92128-65-9 is 73.4°C.

Endpoint:
boiling point
Type of information:
experimental study
Adequacy of study:
key study
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
test procedure in accordance with national standard methods
Qualifier:
according to guideline
Guideline:
other: IP406
Principles of method if other than guideline:
Boiling point range determined by Gas Chromatography
GLP compliance:
no
Remarks:
Study methods are UKAS accredited
Type of method:
other: Boiling point determined by Gas Chromatography
Specific details on test material used for the study:
Test material composition is reflected in the boundary composition and legal entity composition.
Key result
Boiling pt.:
>= 25.5 - <= 98 °C
Atm. press.:
1 atm
Conclusions:
The boiling point of the substance is 25.5 - 98 ºC.
Executive summary:

The boiling point of this substance was determined with Gas Chromatography (method IP406) and was found to be 25.5 - 98 ºC.

Endpoint:
boiling point
Type of information:
experimental study
Adequacy of study:
key study
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
test procedure in accordance with national standard methods
Qualifier:
according to guideline
Guideline:
other: IP406
Principles of method if other than guideline:
Boiling point range determined by Gas Chromatography
GLP compliance:
no
Remarks:
Study methods are UKAS accredited
Type of method:
other: Boiling point determined by Gas Chromatography
Specific details on test material used for the study:
Test material composition is reflected in the boundary composition and legal entity composition.
Key result
Boiling pt.:
>= 62 - <= 99 °C
Atm. press.:
1 atm
Conclusions:
The boiling point of the substance is 62 - 99ºC.
Executive summary:

The boiling point of this substance was determined with Gas Chromatography (method IP406) and was found to be 62 - 99ºC

Endpoint:
boiling point
Type of information:
experimental study
Adequacy of study:
key study
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
test procedure in accordance with national standard methods
Qualifier:
according to guideline
Guideline:
other: IP406
Principles of method if other than guideline:
Boiling point range determined by Gas Chromatography
GLP compliance:
no
Remarks:
Study methods are UKAS accredited
Type of method:
other: Boiling point determined by Gas Chromatography
Specific details on test material used for the study:
Test material composition is reflected in the boundary composition and legal entity composition.
Key result
Boiling pt.:
>= 21 - <= 81.5 °C
Atm. press.:
1 atm
Conclusions:
The boiling point of the substance is 21 - 81.5 ºC.
Executive summary:

The boiling point of this substance was determined with Gas Chromatography (method IP406) and was found to be 21 - 81.5 ºC.

Endpoint:
boiling point
Type of information:
experimental study
Adequacy of study:
key study
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
test procedure in accordance with national standard methods
Qualifier:
according to guideline
Guideline:
other: IP406
Principles of method if other than guideline:
Boiling point range determined by Gas Chromatography
GLP compliance:
no
Remarks:
Study methods are UKAS accredited
Type of method:
other: Boiling point determined by Gas Chromatography
Specific details on test material used for the study:
Test material composition is reflected in the boundary composition and legal entity composition.
Key result
Boiling pt.:
>= -3.5 - <= 103 °C
Atm. press.:
1 atm
Conclusions:
The boiling point of the substance is -3.5 - 103ºC.
Executive summary:

The boiling point of this substance was determined with Gas Chromatography (method IP406) and was found to be -3.5 - 103ºC.

Description of key information

The boiling point of streams in this category is in the range -3.5°C to 103°C.

Key value for chemical safety assessment

Boiling point at 101 325 Pa:
58 °C

Additional information

Data are available for all six streams in this category (64741-84-0: 101.9°C, 64742-49-0: 71.27°C, 92128-65-9: 73.4°C, 68476-55-1: 44.8°C, 102110-14-5: 25 - 48°C) from Chilworth Technology Limited (2009), BASF (2009), GKA competence centre analytics (2009, 2009, 2009) and Deutsche Shell Chemie (2009).

New data areavilable for 4 streams in this category from Intertek (2018):

EC# 265-086-6: 25.5 - 98 ºC,

EC# 265-151-9: 62 - 99ºC,

EC# 295-762-6: -3.5 - 103ºC,

EC# 270-695-5: 21 - 81.5 ºC.

These data will be read across to all category members. The mean of the boiling point values for the category is 53.0°C and this has been used to complete the 'key value for chemical safety assessment'.