Physical & Chemical properties

Viscosity

Currently viewing:

Administrative data

Link to relevant study record(s)

Reference
Endpoint:
viscosity
Type of information:
other: Handbook
Adequacy of study:
key study
Study period:
2000
Reliability:
2 (reliable with restrictions)
Rationale for reliability incl. deficiencies:
data from handbook or collection of data
Qualifier:
no guideline followed
Principles of method if other than guideline:
The method used to determine the viscosity was not reported.
GLP compliance:
no
Type of method:
other: Information not reported.
Key result
Temp.:
other: -25.0°C
Parameter:
dynamic viscosity (in mPa s)
Value:
0.72
Key result
Temp.:
other: 0.0°C
Parameter:
dynamic viscosity (in mPa s)
Value:
0.533
Key result
Temp.:
other: 25.0°C
Parameter:
dynamic viscosity (in mPa s)
Value:
0.405
Key result
Temp.:
other: 50.0°C
Parameter:
dynamic viscosity (in mPa s)
Value:
0.315
Key result
Temp.:
other: 75.0°C
Parameter:
dynamic viscosity (in mPa s)
Value:
0.249
Conclusions:
A dynamic viscosity value of 0.405 mPa.s at 25°C was reported for the substance in a handbook or collection of reliable data which has been subject to peer-review

Description of key information

Viscosity: 0.405 mPa.s at 25°C

Key value for chemical safety assessment

Viscosity:
0.405 mPa · s (dynamic)
at the temperature of:
25 °C

Additional information

A dynamic viscosity value of 0.405 mPa.s at 25°C was reported for the registered substance in a handbook or collection of reliable data which has been subject to peer-review.

In a secondary source to which reliability could not be assigned, a kinematic viscosity value of 0.4 mm2/s at 25°C was reported for the substance.