Registration Dossier
Registration Dossier
Data platform availability banner - registered substances factsheets
Please be aware that this old REACH registration data factsheet is no longer maintained; it remains frozen as of 19th May 2023.
The new ECHA CHEM database has been released by ECHA, and it now contains all REACH registration data. There are more details on the transition of ECHA's published data to ECHA CHEM here.
Diss Factsheets
Use of this information is subject to copyright laws and may require the permission of the owner of the information, as described in the ECHA Legal Notice.
EC number: 275-738-1 | CAS number: 71631-15-7 This substance is identified in the Colour Index by Colour Index Constitution Number, C.I. 77504.
- Life Cycle description
- Uses advised against
- Endpoint summary
- Appearance / physical state / colour
- Melting point / freezing point
- Boiling point
- Density
- Particle size distribution (Granulometry)
- Vapour pressure
- Partition coefficient
- Water solubility
- Solubility in organic solvents / fat solubility
- Surface tension
- Flash point
- Auto flammability
- Flammability
- Explosiveness
- Oxidising properties
- Oxidation reduction potential
- Stability in organic solvents and identity of relevant degradation products
- Storage stability and reactivity towards container material
- Stability: thermal, sunlight, metals
- pH
- Dissociation constant
- Viscosity
- Additional physico-chemical information
- Additional physico-chemical properties of nanomaterials
- Nanomaterial agglomeration / aggregation
- Nanomaterial crystalline phase
- Nanomaterial crystallite and grain size
- Nanomaterial aspect ratio / shape
- Nanomaterial specific surface area
- Nanomaterial Zeta potential
- Nanomaterial surface chemistry
- Nanomaterial dustiness
- Nanomaterial porosity
- Nanomaterial pour density
- Nanomaterial photocatalytic activity
- Nanomaterial radical formation potential
- Nanomaterial catalytic activity
- Endpoint summary
- Stability
- Biodegradation
- Bioaccumulation
- Transport and distribution
- Environmental data
- Additional information on environmental fate and behaviour
- Ecotoxicological Summary
- Aquatic toxicity
- Endpoint summary
- Short-term toxicity to fish
- Long-term toxicity to fish
- Short-term toxicity to aquatic invertebrates
- Long-term toxicity to aquatic invertebrates
- Toxicity to aquatic algae and cyanobacteria
- Toxicity to aquatic plants other than algae
- Toxicity to microorganisms
- Endocrine disrupter testing in aquatic vertebrates – in vivo
- Toxicity to other aquatic organisms
- Sediment toxicity
- Terrestrial toxicity
- Biological effects monitoring
- Biotransformation and kinetics
- Additional ecotoxological information
- Toxicological Summary
- Toxicokinetics, metabolism and distribution
- Acute Toxicity
- Irritation / corrosion
- Sensitisation
- Repeated dose toxicity
- Genetic toxicity
- Carcinogenicity
- Toxicity to reproduction
- Specific investigations
- Exposure related observations in humans
- Toxic effects on livestock and pets
- Additional toxicological data
Eye irritation
Administrative data
- Endpoint:
- eye irritation: in vivo
- Type of information:
- experimental study
- Adequacy of study:
- key study
- Reliability:
- 1 (reliable without restriction)
- Rationale for reliability incl. deficiencies:
- other: see 'Remark'
- Remarks:
- Comparable to guideline study reliable without restrictions Minor deviations from the guideline: - the lot/batch no. of the test substance was not stated. - the relative humidity is slightly higher than 70 % (55 % +/- 25%). - it was not stated, if the eyelids were held together after application of the test substance.
Data source
Reference
- Reference Type:
- study report
- Title:
- Unnamed
- Year:
- 2 000
- Report date:
- 2000
Materials and methods
Test guideline
- Qualifier:
- equivalent or similar to guideline
- Guideline:
- OECD Guideline 405 (Acute Eye Irritation / Corrosion)
- Version / remarks:
- adopted 1987-02-24
- Deviations:
- yes
- Remarks:
- , please refer to "Rationale for reliability incl. deficiencies" above
- GLP compliance:
- no
Test material
- Reference substance name:
- Nickel iron chromite black spinel
- EC Number:
- 275-738-1
- EC Name:
- Nickel iron chromite black spinel
- Cas Number:
- 71631-15-7
- Molecular formula:
- (Ni,Fe)(Fe,Cr)2O4
- IUPAC Name:
- Nickel iron chromite black spinel
- Test material form:
- other: solid
- Details on test material:
- - Name of test material (as cited in study report): NEGRO-G19
Constituent 1
Test animals / tissue source
- Species:
- rabbit
- Strain:
- New Zealand White
- Details on test animals or tissues and environmental conditions:
- TEST ANIMALS
- Weight at study initiation: 2072 grams - 2212 grams
- Housing: individual stainless steel cages, brand Tecniplast; cleaning: automatic
- Diet (daily dose of 150 g): special diet for experimental rabbits, provided by an authorized provider
- Drink: automatic ad libitum, treated and filtered at 5 µm
- Acclimation period: 7 days
At arrival at the Unit, rabbits went through a health control.
ENVIRONMENTAL CONDITIONS
- Temperature: 21 +/- 2 °C
- Relative humidity: 55 % +/- 25 %
- Air: renewed 15 times per hour and prefiltered at 5 µm
- Photoperiod (hrs dark / hrs light): 12/12
Test system
- Vehicle:
- unchanged (no vehicle)
- Controls:
- no
- Amount / concentration applied:
- TEST MATERIAL
- Amount(s) applied (volume or weight with unit): 0.1 g of the solid test item (grinded to fine dust) was administered into the conjunctival bag of one eye by separating the lower eyelid.The untreated eye was used as control. - Observation period (in vivo):
- 1, 24, 48 and 72 hours as well as 7 days after administration of the test substance
- Number of animals or in vitro replicates:
- 3 males
- Details on study design:
- The rabbits were fixed in an immobilization trap during test item administration.
REMOVAL OF TEST SUBSTANCE
not stated
SCORING SYSTEM: Draize scoring system
TOOL USED TO ASSESS SCORE: in order to facilitate the evaluation of the reactions, light from a manual lamp was used and 24 hours after administration of the test item, fluorescein was used to check for injuries of the cornea.
OBSERVATIONS:
- Weight control: it was performed at the beginning of the study
- General examination: the general condition of the animal was observed, as well as the conditions of the eyes. Special attention was given to the apparition of modifications on the treated eye: cornea, iris, conjunctiva, as well as any other injury observed.
Results and discussion
In vivo
Resultsopen allclose all
- Irritation parameter:
- cornea opacity score
- Basis:
- mean
- Remarks:
- animal #1
- Time point:
- other: 24, 48 and 72 hours
- Score:
- 0.33
- Max. score:
- 4
- Reversibility:
- fully reversible within: 48 hours
- Irritation parameter:
- iris score
- Basis:
- mean
- Remarks:
- animal #1
- Time point:
- other: 24, 48 adn 72 hours
- Score:
- 0
- Max. score:
- 2
- Irritation parameter:
- conjunctivae score
- Basis:
- mean
- Remarks:
- animal #1
- Time point:
- other: 24, 48 and 72 hours
- Score:
- 1.67
- Max. score:
- 3
- Reversibility:
- fully reversible within: 7 days
- Irritation parameter:
- chemosis score
- Basis:
- mean
- Remarks:
- animal #1
- Time point:
- other: 24, 48 and 72 hours
- Score:
- 0.67
- Max. score:
- 4
- Reversibility:
- fully reversible within: 72 hours
- Irritation parameter:
- cornea opacity score
- Basis:
- mean
- Remarks:
- animal #2
- Time point:
- other: 24, 48 and 72 hours
- Score:
- 0
- Max. score:
- 4
- Irritation parameter:
- iris score
- Basis:
- mean
- Remarks:
- animal #2
- Time point:
- other: 24, 48 and 72 hours
- Score:
- 0
- Max. score:
- 2
- Irritation parameter:
- conjunctivae score
- Basis:
- mean
- Remarks:
- animal #2
- Time point:
- other: 24, 48 and 72 hours
- Score:
- 1.67
- Max. score:
- 3
- Reversibility:
- fully reversible within: 7 days
- Irritation parameter:
- chemosis score
- Basis:
- mean
- Remarks:
- animal #2
- Time point:
- other: 24, 48 and 72 hours
- Score:
- 0.33
- Max. score:
- 4
- Reversibility:
- fully reversible within: 48 hours
- Irritation parameter:
- cornea opacity score
- Basis:
- mean
- Remarks:
- animal #3
- Time point:
- other: 24, 48 and 72 hours
- Score:
- 0.33
- Max. score:
- 4
- Reversibility:
- fully reversible within: 48 hours
- Irritation parameter:
- iris score
- Basis:
- mean
- Remarks:
- animal #3
- Time point:
- other: 24, 48 and 72 hours
- Score:
- 0.33
- Max. score:
- 2
- Reversibility:
- fully reversible within: 48 hours
- Irritation parameter:
- conjunctivae score
- Basis:
- mean
- Remarks:
- animal #3
- Time point:
- other: 24, 48 and 72 hours
- Score:
- 1.67
- Max. score:
- 3
- Reversibility:
- fully reversible within: 7 days
- Irritation parameter:
- chemosis score
- Basis:
- mean
- Remarks:
- animal #3
- Time point:
- other: 24, 48 and 72 hours
- Score:
- 0.33
- Max. score:
- 4
- Reversibility:
- fully reversible within: 48 hours
- Irritant / corrosive response data:
- Opacity of the cornea of grade 1 affecting 1/4 of the eyeball was observed in two animals at the 1 hour and 24 hour observations. Opacity of the cornea of grade 1 was also observed in the remaining animal at the 1 hour observation.
Injury of the iris of grade 1 was observed in two animals at the 1 hour observation. Injury of the iris of grade 1 was also observed in the remaining animal at the 1 hour and 24 hour observation.
Erythema of the conjunctiva of grade 2 was observed in all animals at the 1 hour, 24 hour and 48 hour observations. The erythema of the conjunctiva changed to a grade 1 in all animals at the 72 hour observation and had disappeared by day 7.
Oedema of the conjunctiva of grade 1 was observed in one animal at the 1 hour, 24 hour and 48 hour observations and in another animal at the 1 hour and 48 hour observation. Oedema of the conjunctiva of grade 2 was observed in the remaining animal at the 1 hour observation , which changed to a grade 1 at the 24 hour observation and had disappeared at the 48 hour observation.
Applicant's summary and conclusion
- Interpretation of results:
- not irritating
- Remarks:
- Migrated information Criteria used for interpretation of results: EU
- Conclusions:
- NEGRO-G19 is not irritating to the eye.
According to the criteria specified by Directive 67/548/EEC and subsequent regulations, the test item is not classified as eye irritant.
According to the EC Regulation No. 1272/2008 and subsequent regulations, the test item is not classified as eye irritant.
Information on Registered Substances comes from registration dossiers which have been assigned a registration number. The assignment of a registration number does however not guarantee that the information in the dossier is correct or that the dossier is compliant with Regulation (EC) No 1907/2006 (the REACH Regulation). This information has not been reviewed or verified by the Agency or any other authority. The content is subject to change without prior notice.
Reproduction or further distribution of this information may be subject to copyright protection. Use of the information without obtaining the permission from the owner(s) of the respective information might violate the rights of the owner.