Registration Dossier

Data platform availability banner - registered substances factsheets

Please be aware that this old REACH registration data factsheet is no longer maintained; it remains frozen as of 19th May 2023.

The new ECHA CHEM database has been released by ECHA, and it now contains all REACH registration data. There are more details on the transition of ECHA's published data to ECHA CHEM here.

Diss Factsheets

Administrative data

Link to relevant study record(s)

Reference
Endpoint:
explosive properties of explosives
Type of information:
experimental study
Adequacy of study:
key study
Study period:
Testing was conducted between 18 March 2010 and 19 March 2010.
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
other: Study conducted in compliance with agreed protocols, with no or minor deviations from standard test guidelines and/or minor methodological deficiencies, which do not affect the quality of the relevant results.
Qualifier:
according to guideline
Guideline:
EU Method A.14 (Explosive properties)
Deviations:
no
GLP compliance:
yes (incl. QA statement)
Parameter:
other: More sensitive to shock than m-dinitrobenzene
Remarks:
migrated information
Remarks on result:
not measured/tested
Parameter:
other: More sensitive to friction than m-dinitrobenzene
Remarks:
migrated information
Remarks on result:
not measured/tested
Parameter:
other: Explosive under influence of flame
Remarks:
migrated information
Remarks on result:
not measured/tested
Parameter:
other: Explosive (not specified)
Remarks:
migrated information
Remarks on result:
negative (not further specified)

Results

BAM fall hammer test

Test

Observations

1

There were no signs of ignition or explosion on impact. When the test assembly was dismantled there were no signs of decomposition.

2

There were no signs of ignition or explosion on impact. When the test assembly was dismantled there were no signs of decomposition.

3

There were no signs of ignition or explosion on impact. When the test assembly was dismantled there were no signs of decomposition.

4

There were no signs of ignition or explosion on impact. When the test assembly was dismantled there were no signs of decomposition.

5

There were no signs of ignition or explosion on impact. When the test assembly was dismantled there were no signs of decomposition.

6

There were no signs of ignition or explosion on impact. When the test assembly was dismantled there were no signs of decomposition.

Result: Negative.

Koenen steel tube test

6 mm Orifice Plate

Test

Time(s)

Observations

1

93

An orange flame from the orifice.

 

108

Burning test item was ejected from the orifice. The orange flame increased in size.

 

147

The orange flame decreased in size.

 

173

The orange flame self-extinguished.

 

300

The test was stopped.

The tube was recovered intact.

2

89

An orange flame from the orifice.

 

100

Burning test item was ejected from the orifice.

 

111

The orange flame increased in size.

 

160

The orange flame decreased in size.

 

178

The orange flame self-extinguished.


 

300

The test was stopped.

The tube was recovered intact.


 

3

88

An orange flame from the orifice.

103

Burning test item was ejected from the orifice.

 

112

The orange flame increased in size.

 

144

The orange flame decreased in size.

 

179

The orange flame self-extinguished.

 

300

The test was stopped.

The tube was recovered intact.

2 mm Orifice Plate

Test

Time(s)

Observations

1

92

An orange flame from the orifice.

 

101

Burning test item was ejected from the orifice.

 

112

The orange flame increased in size.

 

154

The orange flame decreased in size.

 

185

The orange flame self-extinguished.

 

300

The test was stopped.

The tube was recovered intact.

2

93

An orange flame from the orifice.

 

106

Burning test item was ejected from the orifice.

 

117

The orange flame increased in size.

 

158

The orange flame decreased in size.

 

187

The orange flame self-extinguished.

 

300

The test was stopped.

The tube was recovered intact.

3

88

An orange flame from the orifice.

 

99

Burning test item was ejected from the orifice.

 

115

The orange flame increased in size.

 

152

The orange flame decreased in size.

 

178

The orange flame self-extinguished.

 

300

The test was stopped.

The tube was recovered intact.

Result: Negative.

Interpretation of results:
non explosive
Remarks:
Migrated information
Conclusions:
The test item has been determined not to have explosive properties.
Executive summary:

The explosive properties were determined using a method which was designed to be compatible with Method A14 specified in Commission Regulation (EC) No 440/2008 of 30 May 2008.

The test item has been determined not to have explosive properties.

Description of key information

The explosive properties were determined using a method which was designed to be compatible with Method A14 specified in Commission Regulation (EC) No 440/2008 of 30 May 2008.

The test item has been determined not to have explosive properties.

Key value for chemical safety assessment

Explosiveness:
non explosive

Additional information

Justification for classification or non-classification