Registration Dossier
Registration Dossier
Data platform availability banner - registered substances factsheets
Please be aware that this old REACH registration data factsheet is no longer maintained; it remains frozen as of 19th May 2023.
The new ECHA CHEM database has been released by ECHA, and it now contains all REACH registration data. There are more details on the transition of ECHA's published data to ECHA CHEM here.
Diss Factsheets
Use of this information is subject to copyright laws and may require the permission of the owner of the information, as described in the ECHA Legal Notice.
EC number: 929-018-5 | CAS number: 129813-66-7
- Life Cycle description
- Uses advised against
- Endpoint summary
- Appearance / physical state / colour
- Melting point / freezing point
- Boiling point
- Density
- Particle size distribution (Granulometry)
- Vapour pressure
- Partition coefficient
- Water solubility
- Solubility in organic solvents / fat solubility
- Surface tension
- Flash point
- Auto flammability
- Flammability
- Explosiveness
- Oxidising properties
- Oxidation reduction potential
- Stability in organic solvents and identity of relevant degradation products
- Storage stability and reactivity towards container material
- Stability: thermal, sunlight, metals
- pH
- Dissociation constant
- Viscosity
- Additional physico-chemical information
- Additional physico-chemical properties of nanomaterials
- Nanomaterial agglomeration / aggregation
- Nanomaterial crystalline phase
- Nanomaterial crystallite and grain size
- Nanomaterial aspect ratio / shape
- Nanomaterial specific surface area
- Nanomaterial Zeta potential
- Nanomaterial surface chemistry
- Nanomaterial dustiness
- Nanomaterial porosity
- Nanomaterial pour density
- Nanomaterial photocatalytic activity
- Nanomaterial radical formation potential
- Nanomaterial catalytic activity
- Endpoint summary
- Stability
- Biodegradation
- Bioaccumulation
- Transport and distribution
- Environmental data
- Additional information on environmental fate and behaviour
- Ecotoxicological Summary
- Aquatic toxicity
- Endpoint summary
- Short-term toxicity to fish
- Long-term toxicity to fish
- Short-term toxicity to aquatic invertebrates
- Long-term toxicity to aquatic invertebrates
- Toxicity to aquatic algae and cyanobacteria
- Toxicity to aquatic plants other than algae
- Toxicity to microorganisms
- Endocrine disrupter testing in aquatic vertebrates – in vivo
- Toxicity to other aquatic organisms
- Sediment toxicity
- Terrestrial toxicity
- Biological effects monitoring
- Biotransformation and kinetics
- Additional ecotoxological information
- Toxicological Summary
- Toxicokinetics, metabolism and distribution
- Acute Toxicity
- Irritation / corrosion
- Sensitisation
- Repeated dose toxicity
- Genetic toxicity
- Carcinogenicity
- Toxicity to reproduction
- Specific investigations
- Exposure related observations in humans
- Toxic effects on livestock and pets
- Additional toxicological data
Toxicity to microorganisms
Administrative data
Link to relevant study record(s)
- Endpoint:
- activated sludge respiration inhibition testing
- Type of information:
- read-across from supporting substance (structural analogue or surrogate)
- Adequacy of study:
- key study
- Reliability:
- 1 (reliable without restriction)
- Rationale for reliability incl. deficiencies:
- other: see 'Remark'
- Remarks:
- GLP guideline study: The results in this study were consistent with the validity criteria with one exception. The mean oxygen uptake in the blank controls was lower than 20 mg/g*h (17 mg/g*h). The reference substance shows an EC50 in the specified range (usual range of EC50 of the last 20 values in the laboratory was 6.0 - 14.1 mg/L). The used activated sludge which was collected from the same waste water treatment plant showed a maximum oxygen consumption of 36.8 mg/g*h and minimum oxygen consumption of 14.5 mg/g*h of the last 20 measurements. For this the study is classified as valid.
- Justification for type of information:
- A discussion and report on the read across strategy is given as an attachment in IUCLID Section 13.
- Reason / purpose for cross-reference:
- read-across: supporting information
- Qualifier:
- according to guideline
- Guideline:
- OECD Guideline 209 (Activated Sludge, Respiration Inhibition Test
- Deviations:
- no
- GLP compliance:
- yes (incl. QA statement)
- Analytical monitoring:
- no
- Vehicle:
- no
- Details on test solutions:
- PREPARATION AND APPLICATION OF TEST SOLUTION
- Method: Direct addition by initial weight into the test flasks. The test substance was weighed in the required amounts for the test concentrations directly to the test vessels. - Test organisms (species):
- activated sludge, domestic
- Details on inoculum:
- - Laboratory culture: yes, Municipal activated sludge taken from a laboratory wastewater treatment plant (Mannheim, Germany) fed with municipal sewage.
- Preparation of inoculum for exposure: After arrival of the activated sludge suspension in the test facility the suspension was sieved with a fine woven mesh (mesh size about 1 mm). This suspension was pre-aerated over night at room temperature. At the next day the sludge suspension was washed once with drinking water and the suspension was adjusted to 3 g/L Dw. - Test type:
- static
- Water media type:
- freshwater
- Limit test:
- no
- Total exposure duration:
- 3 h
- Test temperature:
- 21.5 - 22 °C
- pH:
- 7.5 - 7.6
- Dissolved oxygen:
- Oxygen concentration during aeration: > 2 mg/L
Oxygen concentration immediately before measurement: > 7 mg/L - Nominal and measured concentrations:
- Nominal: 62.5, 125, 250, 500 and 1000 mg/L
- Details on test conditions:
- TEST SYSTEM
- Test vessel: 1 L glass beakers with 500 mL test solution
- No. of vessels per concentration (replicates): 3
- No. of vessels per control (replicates): 6
TEST MEDIUM / WATER PARAMETERS
- Source/preparation of dilution water: according to OECD guideline
- Intervals of water quality measurement:
OTHER TEST CONDITIONS
- Adjustment of pH: no
EFFECT PARAMETERS MEASURED: After the 3h incubation time the oxygen uptake was measured for a period of about 8 to 10 minutes or until the oxygen concentration fell below 2 mg/L. - Reference substance (positive control):
- yes
- Remarks:
- 3,5-dichlorophenol
- Key result
- Duration:
- 3 h
- Dose descriptor:
- EC10
- Effect conc.:
- > 1 000 mg/L
- Nominal / measured:
- nominal
- Conc. based on:
- test mat.
- Basis for effect:
- inhibition of total respiration
- Remarks:
- respiration rate
- Results with reference substance (positive control):
- According to the test guideline OECD 209 the EC50 values of the reference substance 3,5-dichlorophenol should be in the range of 2-25 mg/L after 3 hours of incubation. The EC50 of the reference substance 3,5-dichlorophenol was in the range of 2-25 mg/L in 3 hours. These results indicate that the microorganisms are responding normally to toxicant stress.
- Validity criteria fulfilled:
- yes
- Remarks:
- The results in this study were consistent with the validity criteria with one exception: oxygen uptake in the blank controls < 20 mg/g*h (=17 mg/g*h). However, the study is classifed as valid (see rational of reliability).
- Conclusions:
- No toxicity of the test substance to activated sludge up to a nominal test concentration of 1000 mg/L was observed. Thus, the EC10 (3h) is determined to be > 1000 mg/L.
- Executive summary:
The study was performed according to OECD guideline 209 under GLP conditions. Nominal test substance concentrations between 62.5 and 1000 mg/L were tested by direct adding the substance to the test vessels. No respiration inhibition was observed in any treatment compared to the control. Thus, the 3h-EC10 value is determined to be > 1000 mg/L based on the nominal concentration.
- Endpoint:
- activated sludge respiration inhibition testing
- Type of information:
- read-across from supporting substance (structural analogue or surrogate)
- Adequacy of study:
- key study
- Study period:
- May 1994
- Reliability:
- 1 (reliable without restriction)
- Rationale for reliability incl. deficiencies:
- other: This robust summary has a reliability rating of 1 because the study followed a standard guideline, followed GLP guidelines, and was conducted without deviations that would invalidate the study.
- Justification for type of information:
- A discussion and report on the read across strategy is given as an attachment in IUCLID Section 13.
- Reason / purpose for cross-reference:
- read-across: supporting information
- Qualifier:
- according to guideline
- Guideline:
- other: Developed by Huls AG (Dr. Schoberl)
- Deviations:
- not specified
- Principles of method if other than guideline:
- Effects were measured by comparing oxygen consumption by the bacterium, Pseudomonas putida, over 5 hours incubation in test systems that contained varying amounts of test substance in comparison to test systems that contained no test substance (control).
- GLP compliance:
- yes
- Analytical monitoring:
- no
- Vehicle:
- no
- Details on test solutions:
- Test systems were 100 ml bottles containing medium. All test systems were stirred through the exposure period. Four innoculated bottles were established per test substance concentration. Two of these bottles at each concentration also contained HgCl2 and acted as autooxidation controls. Four innoculated bottles without test substance and with HgCl2 also acted as controls. Five innoculated bottles without test substance and HgCl2 also acted as controls. All test systems were stirred during the test.
- Test organisms (species):
- Pseudomonas putida
- Details on inoculum:
- The original culture was obtained from the Institut fur Wasser-, Boden- und lufthygiene des BGA (Berlin, Germany).
- Test type:
- static
- Water media type:
- freshwater
- Limit test:
- no
- Total exposure duration:
- 5 h
- Post exposure observation period:
- None
- Test temperature:
- 25.3
- Nominal and measured concentrations:
- Nominal loading levels were 100, 500, 1000, and 2000 ul/L.
- Duration:
- 5 h
- Dose descriptor:
- other: EL0
- Effect conc.:
- 2 other: ml/L
- Nominal / measured:
- nominal
- Conc. based on:
- test mat.
- Basis for effect:
- inhibition of total respiration
- Remarks:
- respiration rate
- Duration:
- 5 h
- Dose descriptor:
- other: EL10
- Effect conc.:
- > 2 other: ml/L
- Nominal / measured:
- nominal
- Conc. based on:
- test mat.
- Basis for effect:
- inhibition of total respiration
- Remarks:
- respiration rate
- Key result
- Duration:
- 5 h
- Dose descriptor:
- other: EL50
- Effect conc.:
- > 2 other: ml/L
- Nominal / measured:
- nominal
- Conc. based on:
- test mat.
- Basis for effect:
- inhibition of total respiration
- Remarks:
- respiration rate
- Key result
- Duration:
- 5 h
- Dose descriptor:
- other: EL100
- Effect conc.:
- > 2 other: ml/L
- Nominal / measured:
- nominal
- Conc. based on:
- test mat.
- Basis for effect:
- inhibition of total respiration
- Remarks:
- respiration rate
- Reported statistics and error estimates:
- None were needed as no effect was measured.
- Validity criteria fulfilled:
- yes
- Conclusions:
- The test substance at the highest loading rate, 2 ml/L, did not inhibit the respiration rate of Pseudomonas putida over an exposure period of 5 hours.
- Executive summary:
The test substance at the highest loading rate, 2 ml/L, did not inhibit the respiration rate of Pseudomonas putida over an exposure period of 5 hours.
Referenceopen allclose all
Description of key information
There is no data available for this substance. However, key data is available for a structural analogues Hydrocarbons, C11-C13 (odd numbered), n-alkanes, <2% aromatics and Isododecane. The data is read across to this substance based on analogue read across and a discussion and report on the read across strategy is provided as an attachment in IUCLID Section 13. Key information is summarised below:
Hydrocarbons, C11-C13 (odd number), n-alkanes, <2% aromatics presented a 3-h EC10 (respiration inhibition) for activated sludge of >1,000 mg/L.
Isododecane presented a 5-h EC50 (respiration rate inhibition) for Pseudomonas putida of >2 mL/L.
Key value for chemical safety assessment
Additional information
Two key studies are available for toxicity to aquatic microorganisms.
The study investigating the toxicity of Hydrocarbons, C11-C13 (odd numbered), n-alkanes, <2% aromatics was performed according to OECD guideline 209 under GLP conditions (BASF, 2014). Nominal test substance concentrations between 62.5 and 1000 mg/L were tested by direct adding the substance to the test vessels. No respiration inhibition was observed in any treatment compared to the control. Thus, the 3h-EC10 value is determined to be > 1000 mg/L based on the nominal concentration.
The study for isododecane measured the effects on microorganisms by comparing oxygen consumption by the bacterium, Pseudomonas putida, over 5 hours incubation in test systems that contained varying amounts of test substance in comparison to test systems that contained no test substance (control). At the highest loading rate, 2 mL/L, this substance did not inhibit the respiration rate of Pseudomonas putida over an exposure period of 5 hours (Sasol, 1994).
Information on Registered Substances comes from registration dossiers which have been assigned a registration number. The assignment of a registration number does however not guarantee that the information in the dossier is correct or that the dossier is compliant with Regulation (EC) No 1907/2006 (the REACH Regulation). This information has not been reviewed or verified by the Agency or any other authority. The content is subject to change without prior notice.
Reproduction or further distribution of this information may be subject to copyright protection. Use of the information without obtaining the permission from the owner(s) of the respective information might violate the rights of the owner.