Registration Dossier

Data platform availability banner - registered substances factsheets

Please be aware that this old REACH registration data factsheet is no longer maintained; it remains frozen as of 19th May 2023.

The new ECHA CHEM database has been released by ECHA, and it now contains all REACH registration data. There are more details on the transition of ECHA's published data to ECHA CHEM here.

Diss Factsheets

Physical & Chemical properties

Particle size distribution (Granulometry)

Administrative data

Endpoint:
particle size distribution (granulometry)
Type of information:
experimental study
Adequacy of study:
key study
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
other: Measurements are performed in an experienced laboratory under supervision of an expert on several samples of the production of the applicant

Data source

Reference
Reference Type:
study report
Title:
Unnamed
Year:
2000
Report date:
2000

Materials and methods

Test guideline
Qualifier:
no guideline followed
Principles of method if other than guideline:
Laserdiffration measurement with dry airflow dispersion
GLP compliance:
no
Type of distribution:
volumetric distribution

Test material

Constituent 1
Chemical structure
Reference substance name:
Diphosphorus pentaoxide
EC Number:
215-236-1
EC Name:
Diphosphorus pentaoxide
Cas Number:
1314-56-3
Molecular formula:
O10P4
IUPAC Name:
tricyclo[3.3.1.1³,⁷]tetraphosphoxane-1,3,5,7-tetrone
Details on test material:
representative material of the production of the applicant
Diphosphorus pentaoxide (hexagonal form) content > 99,5%
Arsenic content chemically bonded as unknown mix oxide, < 200ppm
virtual diphosphorus trioxid content, < 200ppm
representing a low oxygen content by an unknown mixture of several possible low order phosphorus oxides

Results and discussion

Particle sizeopen allclose all
Percentile:
D50
Remarks on result:
other: Migrated from fields under 'Mass median diameter' as D50 percentile. No source field for Standard deviation.
Percentile:
D10
Mean:
0.8 µm
St. dev.:
0.05
Percentile:
other: 16
Mean:
1 µm
St. dev.:
0.1
Percentile:
D50
Mean:
2.9 µm
St. dev.:
0.7
Percentile:
other: 70
Mean:
4.9 µm
St. dev.:
1.3
Percentile:
D90
Mean:
9.7 µm
St. dev.:
3.4

Any other information on results incl. tables

d10 d16 d50 d70 d84 d90
[µm] [µm] [µm] [µm] [µm] [µm]
  average  0,796 0,994 2,900 4,909 7,453 9,736
varianz 0,049 0,100 0,690 1,274 2,157 3,376
measurement No
1 0,72 0,85 1,97 3,14 4,61 5,73
2 0,73 0,86 2,06 3,36 5,05 6,35
3 0,77 0,94 2,49 4,14 6,09 7,52
4 0,8 1,03 3,24 5,75 9,07 11,96
5 0,79 0,98 2,7 4,52 6,79 8,62
6 0,94 1,3 5,32 9,14 13,75 17,17
7 0,72 0,84 1,93 3,03 4,44 5,53
8 0,8 1,01 2,98 5,08 7,6 9,59
9 0,77 0,95 2,52 4,16 6,09 7,53
10 0,8 0,99 2,91 4,88 7,22 9,08
11 0,85 1,1 3,75 6,94 12,01 20,57
12 0,79 0,97 2,73 4,64 7,03 9,13
13 0,81 1,03 3,05 5,08 7,5 9,47
14 0,79 0,97 2,62 4,27 6,17 7,57
15 0,82 1,05 3,14 5,28 8,06 11,75
16 0,78 0,95 2,55 4,2 6,16 7,62
17 0,77 0,93 2,39 3,86 5,55 6,76
19 0,75 0,91 2,26 3,59 5,15 6,24
20 0,77 0,94 2,48 4,06 5,9 7,22
21 0,75 0,9 2,29 3,73 5,44 6,7
22 0,76 0,93 2,49 4,11 5,98 7,34
23 0,82 1,05 3,18 5,43 8,39 11,24
24 0,79 0,98 2,81 4,79 7,18 9,07
25 0,8 1,03 3,26 5,82 9,37 12,79
26 0,83 1,07 3,52 6,38 10,35 13,99
27 0,78 0,96 2,69 4,69 7,32 9,76
28 0,75 0,9 2,22 3,59 5,27 6,54
29 0,77 0,93 2,55 4,39 6,69 8,51
30 0,87 1,13 3,6 5,89 8,7 11,22
31 0,95 1,3 4,79 8,07 12,83 17,26
32 0,83 1,03 3,02 5,01 7,37 9,32
33 0,79 0,99 2,92 5,05 7,67 9,87
34 0,8 1 3,11 5,39 8,07 10,32
35 0,79 0,98 2,78 4,68 6,95 8,73
36 0,81 1,01 3,11 5,47 8,67 12,21
37 0,81 1,01 2,98 5,12 7,8 10,2

Applicant's summary and conclusion

Conclusions:
The average of the d50 value of about 37 samples of the production of the applicant is 2.9µm with a standard deviation of 0,69µm
Executive summary:

The average of the d50 value of about 37 samples of the production of the applicant is 2.9µm with a standard deviation of 0,69µm