Registration Dossier

Data platform availability banner - registered substances factsheets

Please be aware that this old REACH registration data factsheet is no longer maintained; it remains frozen as of 19th May 2023.

The new ECHA CHEM database has been released by ECHA, and it now contains all REACH registration data. There are more details on the transition of ECHA's published data to ECHA CHEM here.

Diss Factsheets

Guidance on Safe Use

Guidance on Safe Use

Currently viewing:

Administrative data

First-aid measures

Eye Contact: Wash immediately and continuously with flowing water for at least 30 minutes.  Remove contact lenses after the first 5 minutes and continue washing. Obtain prompt medical consultation, preferably from an ophthalmologist.  

Skin Contact: Immediately wash skin with soap and plenty of water for at least 15 minutes while removing contaminated clothing and shoes. Obtain medical attention without delay.  Wash clothing before reuse. Destroy contaminated articles such as shoes.  

Inhalation: Move person to fresh air.  If not breathing, give artificial respiration; if by mouth to mouth use rescuer protection (pocket mask, etc).  If breathing is difficult, oxygen should be administered by qualified personnel.  Call a physician or transport to a medical facility.  

Ingestion: Do not induce vomiting. Give one cup (8 ounces or 240 ml) of water or milk if available and transport to a medical facility.   Do not give anything by mouth to an unconscious person.  

Notes to Physician: Due to irritant properties, swallowing may result in burns/ulceration of mouth, stomach and lower gastrointestinal tract with subsequent stricture. Aspiration of vomitus may cause lung injury. Suggest endotracheal/esophageal control if lavage is done.  Respiratory symptoms, including pulmonary edema, may be delayed. Persons receiving significant exposure should be observed 24-48 hours for signs of respiratory distress.  Maintain adequate ventilation and oxygenation of the patient.  Chemical eye burns may require extended irrigation.  Obtain prompt consultation, preferably from an ophthalmologist.  If burn is present, treat as any thermal burn, after decontamination.  No specific antidote.  Treatment of exposure should be directed at the control of symptoms and the clinical condition of the patient.  

Fire-fighting measures

Extinguishing Media: Water fog or fine spray.  Dry chemical fire extinguishers.  Carbon dioxide fire extinguishers.  Foam.  Do not use direct water stream.  Straight or direct water streams may not be effective to extinguish fire.  Alcohol resistant foams (ATC type) are preferred. General purpose synthetic foams (including AFFF) or protein foams may function, but will be less effective.  

Fire Fighting Procedures: Keep people away.  Isolate fire and deny unnecessary entry.  Stay upwind.  Keep out of low areas where gases (fumes) can accumulate.  Water may not be effective in extinguishing fire.  Use water spray to cool fire exposed containers and fire affected zone until fire is out and danger of reignition has passed.  Fight fire from protected location or safe distance. Consider the use of unmanned hose holders or monitor nozzles.  Do not use direct water stream.  May spread fire.  Eliminate ignition sources.  Move container from fire area if this is possible without hazard.  Burning liquids may be moved by flushing with water to protect personnel and minimize property damage.  Avoid accumulation of water.  Product may be carried across water surface spreading fire or contacting an ignition source.  

Special Protective Equipment for Firefighters: Wear positive-pressure self-contained breathing apparatus (SCBA) and protective fire fighting clothing (includes fire fighting helmet, coat, trousers, boots, and gloves).  Avoid contact with this material during fire fighting operations. If contact is likely, change to full chemical resistant fire fighting clothing with self-contained breathing apparatus.  If this is not available, wear full chemical resistant clothing with self-contained breathing apparatus and fight fire from a remote location.

Unusual Fire and Explosion Hazards: Container may vent and/or rupture due to fire.  Vapors are heavier than air and may travel a long distance and accumulate in low lying areas. Ignition and/or flash back may occur.  Flammable mixtures may exist within the vapor space of containers at room temperature.  Flammable concentrations of vapor can accumulate at temperatures above flash point.  

Hazardous Combustion Products: During a fire, smoke may contain the original material in addition to combustion products of varying composition which may be toxic and/or irritating.  Combustion products may include and are not limited to:  Carbon monoxide.  Carbon dioxide.  

Accidental release measures

Steps to be Taken if Material is Released or Spilled: Small spills:  Absorb with materials such as:  Non-combustible material.  Dirt.  Sand.  Large spills:  Dike area to contain spill.  Contain spilled material if possible.  Ground and bond all containers and handling equipment.  Collect in suitable and properly labeled containers.  Pump with explosion-proof equipment.  If available, use foam to smother or suppress.  

Personal Precautions: Evacuate area.  Keep personnel out of low areas.  Keep upwind of spill.  Ventilate area of leak or spill.  No smoking in area.  Only trained and properly protected personnel must be involved in clean-up operations.  Eliminate all sources of ignition in vicinity of spill or released vapor to avoid fire or explosion.  For large spills, warn public of downwind explosion hazard.  Check area with combustible gas detector before reentering area. Ground and bond all containers and handling equipment.  Vapor explosion hazard.  Keep out of sewers.  Use appropriate safety equipment.

Environmental Precautions: Material may float on water and any runoff may create an explosion or fire hazard if ignited.  Prevent from entering into soil, ditches, sewers, waterways and/or groundwater.

Handling and storage

General Handling

Keep away from heat, sparks and flame.  Do not swallow.  Avoid contact with eyes, skin, and clothing.  Avoid breathing vapor.  Wash thoroughly after handling.  Keep container closed.  Use with adequate ventilation.  Never use air pressure for transferring product.  No smoking, open flames or sources of ignition in handling and storage area.  Vapors are heavier than air and may travel a long distance and accumulate in low lying areas. Ignition and/or flash back may occur.  Electrically bond and ground all containers and equipment before transfer or use of material.  Containers, even those that have been emptied, can contain vapors. Do not cut, drill, grind, weld, or perform similar operations on or near empty containers.  Use of non-sparking or explosion-proof equipment may be necessary, depending upon the type of operation.  

Storage

Minimize sources of ignition, such as static build-up, heat, spark or flame.  Keep container closed.  Store in a dry place.  Store away from direct sunlight or ultraviolet light.  Store away from incompatible materials. Maintain inhibitor and dissolved oxygen level. Do not purge containers of this material with nitrogen.  Recommended inhibitor level is:  10 to 20 ppm.  Recommended oxygen level is:  5 to 8 vol. %.  Uninhibited monomer vapors can polymerize and plug relief devices.  Shelf life:  Use within  12 Months; Storage temperature:  < 38 °C

Transport information

Land transport (UN RTDG/ADR/RID)

UN number:
UN1917
Shipping information
Proper shipping name and description:
ETHYL ACRYLATE, STABILIZED
Chemical name:
Ethyl acrylate
Language:
English
Labels:
Class 3 (flammable)
SpecialProvisionsopen allclose all

Inland waterway transport (UN RTDG/ADN(R))

UN number:
UN1917
Shipping information
Proper shipping name and description:
ETHYL ACRYLATE, STABILIZED
Chemical name:
Ethyl acrylate
Language:
English
Labels:
Class 3 (flammable)
Remarksopen allclose all

Marine transport (UN RTDG/IMDG)

UN number:
UN1917
Shipping information
Proper shipping name and description:
ETHYL ACRYLATE, STABILIZED
Chemical name:
Ethyl acrylate
Labels:
Class 3 (flammable)
Remarksopen allclose all

Air transport (UN RTDG/ICAO/IATA)

UN number:
UN1917
Shipping information
Proper shipping name and description:
ETHYL ACRYLATE, STABILIZED
Chemical name:
Ethyl acrylate
Labels:
Class 3 (flamable)
Special provisions / remarks
Remarks:
Cargo Packing Instruction: 307
Passenger Packing Instruction: 305
SpecialProvisionsopen allclose all

Exposure controls / personal protection

Eye/Face Protection: Use chemical goggles.  Chemical goggles should be consistent with EN 166 or equivalent.  If exposure causes eye discomfort, use a full-face respirator.  

Skin Protection: Use protective clothing chemically resistant to this material.  Selection of specific items such as face shield, boots, apron, or full body suit will depend on the task.  Safety shower should be located in immediate work area.  Remove contaminated clothing immediately, wash skin area with soap and water, and launder clothing before reuse or dispose of properly.  Items which cannot be decontaminated, such as shoes, belts and watchbands, should be removed and disposed of properly.  

Hand protection: Use chemical resistant gloves classified under Standard EN374: Protective gloves against chemicals and micro-organisms.  Examples of preferred glove barrier materials include:  Chlorinated polyethylene.  Polyethylene.  Ethyl vinyl alcohol laminate ("EVAL").  Polyvinyl alcohol ("PVA").  Styrene/butadiene rubber.  Examples of acceptable glove barrier materials include:  Butyl rubber.  Nitrile/butadiene rubber ("nitrile" or "NBR").  Polyvinyl chloride ("PVC" or "vinyl").  Viton.  Avoid gloves made of:  Neoprene.  When prolonged or frequently repeated contact may occur, a glove with a protection class of 5 or higher (breakthrough time greater than 240 minutes according to EN 374) is recommended.  When only brief contact is expected, a glove with a protection class of 3 or higher (breakthrough time greater  than 60 minutes according to EN 374) is recommended.  NOTICE: The selection of a specific glove for a particular application and duration of use in a workplace should also take into account all relevant workplace factors such as, but not limited to: Other chemicals which may be handled, physical requirements (cut/puncture protection, dexterity, thermal protection), potential body reactions to glove materials, as well as the instructions/specifications provided by the glove supplier.  

Respiratory Protection: Respiratory protection should be worn when there is a potential to exceed the exposure limit requirements or guidelines.  If there are no applicable exposure limit requirements or guidelines, use an approved respirator.  Selection of air-purifying or positive-pressure supplied-air will depend on the specific operation and the potential airborne concentration of the material.  For emergency conditions, use an approved positive-pressure self-contained breathing apparatus.  In confined or poorly ventilated areas, use an approved self-contained breathing apparatus or positive pressure air line with auxiliary self-contained air supply.  Use the following CE approved air-purifying respirator:  Organic vapor cartridge, type A (boiling point >65 ºC)

 

Ingestion: Avoid ingestion of even very small amounts; do not consume or store food or tobacco in the work area; wash hands and face before smoking or eating.  

Engineering Controls / Ventilation: Use engineering controls to maintain airborne level below exposure limit requirements or guidelines.  If there are no applicable exposure limit requirements or guidelines, use only with adequate ventilation.  Local exhaust ventilation may be necessary for some operations.  

Stability and reactivity

Stable under recommended storage conditions.  Unstable at elevated temperatures.  Hygroscopic.  

Conditions to Avoid: Avoid temperatures above  38°C (100°F)  Exposure to elevated temperatures can cause product to decompose.  Avoid static discharge.  Avoid moisture.  Do not blanket or purge with an inert gas to avoid depleting the oxygen concentration.  Avoid direct sunlight or ultraviolet sources.  

Inhibitor: Mequinol; 4-methoxyphenol; hydroquinone monomethyl ether.  Inhibitor Concentration (ppm):  10 - 990

Incompatible Materials: Avoid contact with oxidizing materials.  Avoid contact with:  Aldehydes.  Amines.  Azides.  Ethers.  Free radical initiators.  Halides.  Mercaptans.  Mineral acids.  Peroxides.  Strong inorganic bases.  Avoid contact with metals such as:  Brass.  Copper.  Avoid unintended contact with:  Activated carbon.  Avoid contact with absorbent materials such as:  Clay-based absorbents.  Aluminum oxide.  Silica gel.  Avoid unintended contact with peroxides.  

Hazardous Polymerization: Can occur.  Elevated temperatures can cause hazardous polymerization.  Maintain inhibitor and dissolved oxygen level. Do not purge containers of this material with nitrogen.  Polymerization can be catalyzed by:  Absence of air.  Free radical initiators.  High temperature.  Peroxides.  Presence of water can accelerate rate of polymerization.  Uninhibited monomer vapors can polymerize and plug relief devices.  

Thermal Decomposition: Decomposition products depend upon temperature, air supply and the presence of other materials.  

Disposal considerations

This product, when being disposed of in its unused and uncontaminated state should be treated as a hazardous waste according to EC Directive 91/689/EEC.  Any disposal practices must be in compliance with all national and provincial laws and any municipal or local by-laws governing hazardous waste.  For used, contaminated and residual materials additional evaluations may be required.  Do not dump into any sewers, on the ground, or into any body of water.