surface tension
Type of information:
migrated information: read-across from supporting substance (structural analogue or surrogate)
Adequacy of study:
key study
Study period:
19 Apr - 12 Jul 2010
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
other: GLP guideline study
Qualifier:
according to guideline
Guideline:
OECD Guideline 115 (Surface Tension of Aqueous Solutions)
Qualifier:
according to guideline
Guideline:
EU Method A.5 (Surface Tension)
GLP compliance:
yes (incl. QA statement)
Remarks:
Food and Consumer Product Safety Authority (VWA), Den Haag, The Netherlands
Type of method:
ring method
Surface tension:
74.3 mN/m
Temp.:
20 °C
Conc.:
1 g/L

Table: Surface tension of the test substance

Measurement

Time passed

[minutes]

Surface tension [mN/m]

individual

mean(1)

mean multiplied by Ob and Harkins-Jordan

corrected value

1

20

70.4

73.9

74.3

2

21

72.1

 

 

3

22

72.9

 

 

4

23

73.3

 

 

5

24

73.5

 

 

6

25

73.8

 

 

7

26

73.8

 

 

8

27

74.0

 

 

9

28

73.9

 

 

10

29

73.9

 

 

(1) Mean calculated from measurements 6 to 10, after equilibrium was reached

Conclusions:
The OECD harmonized ring method was used for the determination of the surface tension of sodium aluminate. The surface tension of a test solution at a concentration of 1 g/L in water and at 20 °C was 74.3 mN/m. According to this, the test substance is considered not to be surface active.
Executive summary:

The OECD harmonized ring method was used for the determination of the surface tension of sodium aluminate. The surface tension of a test solution at a concentration of 1 g/L in water and at 20 °C was 74.3 mN/m. According to this, the test substance is considered not to be surface active.

Description of key information

The surface tension of a test solution at a concentration of 1 g/L in water and at 20 °C was 74.3 mN/m.

Key value for chemical safety assessment

Surface tension:
74.3
in mN/m at 20°C and concentration in mg/L:
1 000

Additional information

Test result refers to sodium aluminate (NaAlO2) aqueous solution (38.3%) containing excess disodium oxide (Na2O) as stabiliser.

The OECD harmonized ring method was used for the determination of the surface tension of sodium aluminate. The surface tension of a test solution at a concentration of 1 g/L in water and at 20 °C was 74.3 mN/m (Brekelmans 2010). According to this, the test substance is considered not to be surface active.