Registration Dossier

Diss Factsheets

Physical & Chemical properties

Oxidising properties

Currently viewing:

Administrative data

Link to relevant study record(s)

Description of key information

Non-oxidizing

Key value for chemical safety assessment

Oxidising properties:
non oxidising

Additional information

The determination was performed according to EEC Directive 92/69, A.17.

In the full test, the maximum burning rate of test mixture is lower than the maximum burning rate of the reference mixture of cellulose and barium nitrate. The ratio was calculated to be 0.43

Justification for classification or non-classification

As the experimental data provided the test substance is not considerded to be classified as an oxidising material.