Registration Dossier

Diss Factsheets

Administrative data

Endpoint:
vapour pressure
Type of information:
experimental study
Adequacy of study:
key study
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
other: GLP

Data source

Reference
Reference Type:
study report
Title:
Unnamed
Year:
1999
Report date:
1999

Materials and methods

Test guideline
Qualifier:
according to guideline
Guideline:
other: 92/69/EWG, A.4 (Dynamische Methode)
GLP compliance:
yes
Type of method:
dynamic method

Test material

Results and discussion

Vapour pressureopen allclose all
Temp.:
135 °C
Vapour pressure:
100 Pa
Remarks on result:
other: Second vapour pressure
Temp.:
20 °C
Vapour pressure:
0.021 Pa
Remarks on result:
other: Estimated vapour pressure value.

Applicant's summary and conclusion