Registration Dossier
Registration Dossier
Diss Factsheets
Use of this information is subject to copyright laws and may require the permission of the owner of the information, as described in the ECHA Legal Notice.
EC number: 406-080-7 | CAS number: 83016-70-0 JEFFCAT ZF-10; TEXACAT ZF-10
- Life Cycle description
- Uses advised against
- Endpoint summary
- Appearance / physical state / colour
- Melting point / freezing point
- Boiling point
- Density
- Particle size distribution (Granulometry)
- Vapour pressure
- Partition coefficient
- Water solubility
- Solubility in organic solvents / fat solubility
- Surface tension
- Flash point
- Auto flammability
- Flammability
- Explosiveness
- Oxidising properties
- Oxidation reduction potential
- Stability in organic solvents and identity of relevant degradation products
- Storage stability and reactivity towards container material
- Stability: thermal, sunlight, metals
- pH
- Dissociation constant
- Viscosity
- Additional physico-chemical information
- Additional physico-chemical properties of nanomaterials
- Nanomaterial agglomeration / aggregation
- Nanomaterial crystalline phase
- Nanomaterial crystallite and grain size
- Nanomaterial aspect ratio / shape
- Nanomaterial specific surface area
- Nanomaterial Zeta potential
- Nanomaterial surface chemistry
- Nanomaterial dustiness
- Nanomaterial porosity
- Nanomaterial pour density
- Nanomaterial photocatalytic activity
- Nanomaterial radical formation potential
- Nanomaterial catalytic activity
- Endpoint summary
- Stability
- Biodegradation
- Bioaccumulation
- Transport and distribution
- Environmental data
- Additional information on environmental fate and behaviour
- Ecotoxicological Summary
- Aquatic toxicity
- Endpoint summary
- Short-term toxicity to fish
- Long-term toxicity to fish
- Short-term toxicity to aquatic invertebrates
- Long-term toxicity to aquatic invertebrates
- Toxicity to aquatic algae and cyanobacteria
- Toxicity to aquatic plants other than algae
- Toxicity to microorganisms
- Endocrine disrupter testing in aquatic vertebrates – in vivo
- Toxicity to other aquatic organisms
- Sediment toxicity
- Terrestrial toxicity
- Biological effects monitoring
- Biotransformation and kinetics
- Additional ecotoxological information
- Toxicological Summary
- Toxicokinetics, metabolism and distribution
- Acute Toxicity
- Irritation / corrosion
- Sensitisation
- Repeated dose toxicity
- Genetic toxicity
- Carcinogenicity
- Toxicity to reproduction
- Specific investigations
- Exposure related observations in humans
- Toxic effects on livestock and pets
- Additional toxicological data

Vapour pressure
Administrative data
Link to relevant study record(s)
- Endpoint:
- vapour pressure
- Type of information:
- experimental study
- Adequacy of study:
- key study
- Study period:
- 1990-05-30 to 1990-05-31
- Reliability:
- 1 (reliable without restriction)
- Rationale for reliability incl. deficiencies:
- guideline study
- Qualifier:
- according to guideline
- Guideline:
- EU Method A.4 (Vapour Pressure)
- Qualifier:
- equivalent or similar to guideline
- Guideline:
- OECD Guideline 104 (Vapour Pressure Curve)
- GLP compliance:
- yes (incl. QA statement)
- Type of method:
- isoteniscope
- Specific details on test material used for the study:
- - Name of test material (as cited in study report): Texacat ZF-10, 2-[[2-[2-(dimethylamino)ethoxy]ethyl]methylamino]ethanol
- Physical state: Clear colourless liquid
- Analytical purity: 97%
- Lot/batch No.: 90/329
- Expiration date of the lot/batch: Approximately two years from receipt (received on 30 March 1990)
- Storage condition of test material: Dark at room temperature - Key result
- Temp.:
- 25 °C
- Vapour pressure:
- 12 Pa
- Remarks on result:
- other: ± 4 Pa
- Conclusions:
- The vapour pressure of the test substance has been determined as 12 ± 4 Pa at 25°C (298K).
- Endpoint:
- vapour pressure
- Type of information:
- experimental study
- Adequacy of study:
- supporting study
- Study period:
- 2003-02-26 to 2003-06-05
- Reliability:
- 1 (reliable without restriction)
- Rationale for reliability incl. deficiencies:
- guideline study
- Qualifier:
- according to guideline
- Guideline:
- OECD Guideline 104 (Vapour Pressure Curve)
- GLP compliance:
- no
- Remarks:
- Test facility was not GLP recognized.
- Type of method:
- isoteniscope
- Specific details on test material used for the study:
- - Name of test material (as cited in study report): Jeffcat ZF-10, 2-((2-(2-(dimethylamino)ethoxy)ethyl)methyl-amino)-ethanol
- Substance type: Amine
- Physical state: Clear colourless liquid
- Analytical purity: 99%
- Lot/batch No.: 324756
- Storage condition of test material: 22 °C in the dark - Temp.:
- 0 °C
- Vapour pressure:
- 1.33 Pa
- Temp.:
- 10 °C
- Vapour pressure:
- 3.2 Pa
- Key result
- Temp.:
- 25 °C
- Vapour pressure:
- 10 Pa
- Temp.:
- 30 °C
- Vapour pressure:
- 13.33 Pa
- Temp.:
- 40 °C
- Vapour pressure:
- 28 Pa
- Temp.:
- 50 °C
- Vapour pressure:
- 53.33 Pa
- Conclusions:
- The vapor pressure was determined to be 10 Pa at 25°C.
Referenceopen allclose all
The isoteniscope method was employed for vapour pressure determination (American Society for Testing Materials: ASTM D2879-92, as recommended by the OECD).
Description of key information
The vapour pressure of the test substance was determined to be 12 ± 4 Pa at 25°C (298K) in a GLP-compliant study conducted according to methods described in EEC Directive 67/548, Annex V, A4. as published in 84/449/EEC and similar to the OECD guideline 104 performed by Huntingdon Research Centre Ltd. (1990).
The study was considered to be reliable without restrictions (Klimisch 1).
Key value for chemical safety assessment
- Vapour pressure:
- 12 Pa
- at the temperature of:
- 25 °C
Additional information
A supporting study performed according to the OECD 104, performed by BC Research Inc. (20003) and considered reliable without restrictions and reports a vapour pressure of 10 Pa at 25°C which is in line with the key value.
Information on Registered Substances comes from registration dossiers which have been assigned a registration number. The assignment of a registration number does however not guarantee that the information in the dossier is correct or that the dossier is compliant with Regulation (EC) No 1907/2006 (the REACH Regulation). This information has not been reviewed or verified by the Agency or any other authority. The content is subject to change without prior notice.
Reproduction or further distribution of this information may be subject to copyright protection. Use of the information without obtaining the permission from the owner(s) of the respective information might violate the rights of the owner.