Registration Dossier

Data platform availability banner - registered substances factsheets

Please be aware that this old REACH registration data factsheet is no longer maintained; it remains frozen as of 19th May 2023.

The new ECHA CHEM database has been released by ECHA, and it now contains all REACH registration data. There are more details on the transition of ECHA's published data to ECHA CHEM here.

Diss Factsheets

Administrative data

Endpoint:
eye irritation
Remarks:
other: prediction from hazard class
Type of information:
calculation (if not (Q)SAR)
Remarks:
Migrated phrase: estimated by calculation
Adequacy of study:
key study
Reliability:
2 (reliable with restrictions)
Rationale for reliability incl. deficiencies:
other: Automatic calculation with MeCLas tool.
Cross-referenceopen allclose all
Reason / purpose for cross-reference:
reference to same study
Reason / purpose for cross-reference:
reference to other study

Data source

Reference
Reference Type:
other: software
Title:
Unnamed
Year:
2014

Materials and methods

Principles of method if other than guideline:
Eye irritation/corrosion potential of the UVCB potential was determined by classifying based on Mixture rules from EU CLP (additivity formula of classified components to derive hazard class). The classification criteria were used to estimate effects.

Test material

Constituent 1
Details on test material:
Reasonable worst-case across industry, as reported in Section 1.2.
Representative sample for mineralogical information is provided in IUCLID section 4.23.

Results and discussion

Any other information on results incl. tables

According to MeClas, the substance is classified as Eye corrosive Cat. 1 - H318.

Applicant's summary and conclusion

Interpretation of results:
Category 1 (irreversible effects on the eye)
Remarks:
Migrated information
Conclusions:
Good quality study with result derived on basis of the Classification outcome (Mixture toxicity rules) from the reasinable worst case sample of the substance (maximum of typicals across industry as defined in IUCLID section 1.2/4.23). The analysed UVCB sample is classified for eye corrosive.
Executive summary:

The study provided a conservative estimate, derived on basis of the classification outcome (mixture toxicity rules) from a reasonable worst-case sample of the substance using mineralogical information from the representative sample. 

 

Validity of the model used:

1. Defined endpoint: the endpoint is a REACH compliant defined endpoint

2. Unambiguous algorithm: EU CLP guidance based summation formula to determine classification, followed by back-calculation to related hazard criteria

3. Applicability domain: applicable to classify complex metal containing materials. 

4. Mechanistic interpretation - metal species: the tool translates the elemental composition into a mineralogical composition relevant for classification.