Registration Dossier
Registration Dossier
Diss Factsheets
Use of this information is subject to copyright laws and may require the permission of the owner of the information, as described in the ECHA Legal Notice.
EC number: 240-539-0 | CAS number: 16484-77-8
- Life Cycle description
- Uses advised against
- Endpoint summary
- Appearance / physical state / colour
- Melting point / freezing point
- Boiling point
- Density
- Particle size distribution (Granulometry)
- Vapour pressure
- Partition coefficient
- Water solubility
- Solubility in organic solvents / fat solubility
- Surface tension
- Flash point
- Auto flammability
- Flammability
- Explosiveness
- Oxidising properties
- Oxidation reduction potential
- Stability in organic solvents and identity of relevant degradation products
- Storage stability and reactivity towards container material
- Stability: thermal, sunlight, metals
- pH
- Dissociation constant
- Viscosity
- Additional physico-chemical information
- Additional physico-chemical properties of nanomaterials
- Nanomaterial agglomeration / aggregation
- Nanomaterial crystalline phase
- Nanomaterial crystallite and grain size
- Nanomaterial aspect ratio / shape
- Nanomaterial specific surface area
- Nanomaterial Zeta potential
- Nanomaterial surface chemistry
- Nanomaterial dustiness
- Nanomaterial porosity
- Nanomaterial pour density
- Nanomaterial photocatalytic activity
- Nanomaterial radical formation potential
- Nanomaterial catalytic activity
- Endpoint summary
- Stability
- Biodegradation
- Bioaccumulation
- Transport and distribution
- Environmental data
- Additional information on environmental fate and behaviour
- Ecotoxicological Summary
- Aquatic toxicity
- Endpoint summary
- Short-term toxicity to fish
- Long-term toxicity to fish
- Short-term toxicity to aquatic invertebrates
- Long-term toxicity to aquatic invertebrates
- Toxicity to aquatic algae and cyanobacteria
- Toxicity to aquatic plants other than algae
- Toxicity to microorganisms
- Endocrine disrupter testing in aquatic vertebrates – in vivo
- Toxicity to other aquatic organisms
- Sediment toxicity
- Terrestrial toxicity
- Biological effects monitoring
- Biotransformation and kinetics
- Additional ecotoxological information
- Toxicological Summary
- Toxicokinetics, metabolism and distribution
- Acute Toxicity
- Irritation / corrosion
- Sensitisation
- Repeated dose toxicity
- Genetic toxicity
- Carcinogenicity
- Toxicity to reproduction
- Specific investigations
- Exposure related observations in humans
- Toxic effects on livestock and pets
- Additional toxicological data

Surface tension
Administrative data
Link to relevant study record(s)
- Endpoint:
- surface tension
- Type of information:
- experimental study
- Adequacy of study:
- key study
- Study period:
- 02 February 1999 to 22 June 1999
- Reliability:
- 1 (reliable without restriction)
- Rationale for reliability incl. deficiencies:
- guideline study
- Qualifier:
- according to guideline
- Guideline:
- OECD Guideline 115 (Surface Tension of Aqueous Solutions)
- Deviations:
- no
- Qualifier:
- according to guideline
- Guideline:
- EU Method A.5 (Surface Tension)
- Deviations:
- no
- GLP compliance:
- yes
- Type of method:
- OECD harmonised ring method
- Key result
- Surface tension:
- 50 mN/m
- Temp.:
- 20 °C
- Conc.:
- 90 vol%
- Conclusions:
- Under the conditions of the study the surface tension of a 90 % saturated solution of the test material was found to be 50.0 mN/m. As the result is less than 60 mN/m, the test material is considered to be surface active.
- Executive summary:
The surface tension of the test material was assessed according to OECD Test Guideline 115 EU Method A.5. and in compliance with GLP using the OECD harmonized ring method.
Test material (approximately 79.2 mg) was dissolved in purified water (100 mL) to give a 90 % saturated aqueous solution.
A second solution was prepared in a similar manner.
The test vessel was half filled with liquid, put on the tensiometer test platform, and raised so that the ring was 2 - 3 mm below the liquid surface. The platform was lowered to draw a lamella from the liquid surface. The maximum force which arose just before the lamella was torn off is the surface tension and was recorded. Measurements were made at intervals until a constant value (to within 0.5 mN/m) was recorded. The room temperature was monitored throughout the test.
From the results there was no apparent time dependence of surface tension after transfer to the measuring vessel.
Under the conditions of the study the surface tension of a 90 % saturated solution of the test material was found to be 50.0 mN/m. As the result is less than 60 mN/m, the test material (pure grade) is considered to be surface active.
- Endpoint:
- surface tension
- Type of information:
- experimental study
- Adequacy of study:
- supporting study
- Study period:
- 12 September 1994
- Reliability:
- 2 (reliable with restrictions)
- Rationale for reliability incl. deficiencies:
- guideline study without detailed documentation
- Qualifier:
- according to guideline
- Guideline:
- other: DIN 53914
- Deviations:
- not specified
- GLP compliance:
- yes (incl. QA statement)
- Type of method:
- ring method
- Key result
- Surface tension:
- 51.4 mN/m
- Temp.:
- 20 °C
- Conc.:
- 0.5 other: % (w/w)
- Key result
- Surface tension:
- 51.6 mN/m
- Temp.:
- 20 °C
- Conc.:
- 2 other: % (w/w)
- Conclusions:
- Under the conditions of the study the surface tension of 0.5 % and 2 % (w/w in pure water) concentrations of the test material were 51.4mN/m and 51.6mN/m respectively.
- Executive summary:
The surface tension of the test material was assessed according to DIN 53914 and in compliance with GLP using the ring method of Lecomte du Nouy.
Under the conditions of the study the surface tension of 0.5 % and 2 % (w/w in pure water) concentrations of the test material were 51.4mN/m and 51.6mN/m respectively.
Referenceopen allclose all
Surface Tension
Time (Minutes) |
Surface Tension (mN/m) |
|||
Measured |
Calibration Corrected |
|||
A |
B |
A |
B |
|
0 |
51.5 |
52.5 |
52.0 |
53.0 |
10 |
52.0 |
52.5 |
52.5 |
53.0 |
20 |
52.0 |
52.5 |
52.5 |
53.0 |
30 |
51.5 |
52.5 |
53.0 |
53.0 |
From the results there was no apparent time dependence of surface tension after transfer to the measuring vessel.
Overall mean calibration corrected surface tension = 52.5 mN/m
Harkins-Jordan corrected value = 50.0 mN/m
Surface tension: 51.4mN/m with a 0.5 % concentration of the test material (w/w in pure water).
Surface tension: 51.6mN/m with a 2% concentration of the test material (w/w in pure water).
Description of key information
Comb (2000b)
Under the conditions of the study the surface tension of a 90 % saturated solution of the test material was found to be 50.0 mN/m. As the result is less than 60 mN/m, the test material (pure grade) is considered to be surface active.
Supporting Study: Kröhl (1994)
Under the conditions of the study the surface tension of 0.5 % and 2 % (w/w in pure water) concentrations of the test material were 51.4mN/m and 51.6mN/m respectively.
Key value for chemical safety assessment
- Surface tension:
- 50
Additional information
Comb (2000b)
The surface tension of the test material was assessed according to OECD Test Guideline 115 EU Method A.5. and in compliance with GLP using the OECD harmonised ring method. The study was awarded a reliability score of 1 in accordance with the criteria set forth by Klimisch et al. (1997).
Test material (approximately 79.2 mg) was dissolved in purified water (100 mL) to give a 90 % saturated aqueous solution.
A second solution was prepared in a similar manner.
The test vessel was half filled with liquid, put on the tensiometer test platform, and raised so that the ring was 2 - 3 mm below the liquid surface. The platform was lowered to draw a lamella from the liquid surface. The maximum force which arose just before the lamella was torn off is the surface tension and was recorded. Measurements were made at intervals until a constant value (to within 0.5 mN/m) was recorded. The room temperature was monitored throughout the test.
From the results there was no apparent time dependence of surface tension after transfer to the measuring vessel.
Under the conditions of the study the surface tension of a 90 % saturated solution of the test material was found to be 50.0 mN/m. As the result is less than 60 mN/m, the test material (pure grade) is considered to be surface active.
Supporting Study: Kröhl (1994)
The surface tension of the test material was assessed according to DIN 53914 and in compliance with GLP using the ring method of Lecomte du Nouy. The study was awarded a reliability score of 2 in accordance with the criteria set forth by Klimisch et al. (1997).
Under the conditions of the study the surface tension of 0.5 % and 2 % (w/w in pure water) concentrations of the test material were 51.4mN/m and 51.6mN/m respectively.
Information on Registered Substances comes from registration dossiers which have been assigned a registration number. The assignment of a registration number does however not guarantee that the information in the dossier is correct or that the dossier is compliant with Regulation (EC) No 1907/2006 (the REACH Regulation). This information has not been reviewed or verified by the Agency or any other authority. The content is subject to change without prior notice.