Registration Dossier

Data platform availability banner - registered substances factsheets

Please be aware that this old REACH registration data factsheet is no longer maintained; it remains frozen as of 19th May 2023.

The new ECHA CHEM database has been released by ECHA, and it now contains all REACH registration data. There are more details on the transition of ECHA's published data to ECHA CHEM here.

Diss Factsheets

Administrative data

Endpoint:
flash point
Type of information:
experimental study
Adequacy of study:
key study
Study period:
2012
Reliability:
2 (reliable with restrictions)
Rationale for reliability incl. deficiencies:
other: Non-GLP study conducted according to ASTM guideline

Data source

Reference
Reference Type:
study report
Title:
Unnamed
Year:
2012
Report date:
2012

Materials and methods

Test guideline
Qualifier:
according to guideline
Guideline:
ISO No., other: ASTM D93
Principles of method if other than guideline:
ASTM D93 - 11 Standard Test Methods for Flash Point by Pensky-Martens Closed Cup Tester
GLP compliance:
no
Type of method:
closed cup

Test material

Constituent 1
Chemical structure
Reference substance name:
(6E)-2,6-dimethyl-10-methylidenedodeca-2,6-diene; (6E)-3,7,11-trimethyldodeca-1,6,10-triene; (6E,10E)-2,6,10-trimethyldodeca-2,6,10-triene; (6E,10Z)-2,6,10-trimethyldodeca-2,6,10-triene
EC Number:
942-471-3
Cas Number:
1581740-29-5
Molecular formula:
C15H26
IUPAC Name:
(6E)-2,6-dimethyl-10-methylidenedodeca-2,6-diene; (6E)-3,7,11-trimethyldodeca-1,6,10-triene; (6E,10E)-2,6,10-trimethyldodeca-2,6,10-triene; (6E,10Z)-2,6,10-trimethyldodeca-2,6,10-triene
Test material form:
other: liquid
Details on test material:
Batch: RV-650-70-2
Sample ID: 2012-SANF-000190-028

Results and discussion

Flash point
Flash point:
ca. 234 °F
Atm. press.:
760 mm Hg

Applicant's summary and conclusion

Conclusions:
The Flash Point was determined to be 234 F
Not a flammable liquid per REACH CLP guidelines.
Executive summary:

The flash point of farnesane was measured experimenatlly according to method ASTM D93 -11 (Pensky-Martens closed cup). The flash point (closed cup) was 234 F