Registration Dossier

Diss Factsheets

Physical & Chemical properties

Flash point

Currently viewing:

Administrative data

Link to relevant study record(s)

Reference
Endpoint:
flash point of flammable liquids
Type of information:
experimental study
Adequacy of study:
key study
Reliability:
2 (reliable with restrictions)
Rationale for reliability incl. deficiencies:
other: Test procedure in accordance with national standard methods (ASTM) without GLP.
Qualifier:
equivalent or similar to guideline
Guideline:
ISO 2719 (Determination of flash point - Pensky-Martens closed cup method)
Version / remarks:
2002
Deviations:
no
GLP compliance:
not specified
Type of method:
closed cup
Flash point:
92 °C
Atm. press.:
ca. 1 atm

The registered substance was tested according to ASTM D445 resulting in a corrected flash point value of 92 °C (198 °F).

Conclusions:
Corrected flash point is 92 °C (198 °F).
Executive summary:

Corrected flash point is 92 °C (198 °F).

Description of key information

Key value for chemical safety assessment

Flash point at 101 325 Pa:
92 °C

Additional information

The substance was determined in a reliable study. The flash point was determined to be 92 °C.