Environmental fate & pathways

Biodegradation in water: screening tests

Administrative data

Endpoint:
biodegradation in water: ready biodegradability
Type of information:
experimental study
Adequacy of study:
key study
Study period:
13-aug-2007 to 11-sep-2007
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
other: The study has been performed according to OECD and EC guidelines and according to GLP principles.

Data source

Reference
Reference Type:
study report
Title:
Unnamed
Year:
2007
Report date:
2007

Materials and methods

Test guidelineopen allclose all
Qualifier:
according to guideline
Guideline:
EU Method C.4-E (Determination of the "Ready" Biodegradability - Closed Bottle Test)
Deviations:
no
Qualifier:
according to guideline
Guideline:
OECD Guideline 301 D (Ready Biodegradability: Closed Bottle Test)
Deviations:
no
GLP compliance:
yes

Test material

Constituent 1
Chemical structure
Reference substance name:
tert-butyl N-[(1S,3S,4S)-4-hydroxy-4-[4-methoxy-3-(3-methoxypropoxy)phenyl]-1-[(2S,4S)-5-oxo-4-(propan-2-yl)oxolan-2-yl]-3-(propan-2-yl)butyl]carbamate
EC Number:
700-317-0
Cas Number:
934841-33-5
Molecular formula:
C30H49NO8
IUPAC Name:
tert-butyl N-[(1S,3S,4S)-4-hydroxy-4-[4-methoxy-3-(3-methoxypropoxy)phenyl]-1-[(2S,4S)-5-oxo-4-(propan-2-yl)oxolan-2-yl]-3-(propan-2-yl)butyl]carbamate
Details on test material:
- Name of test material (as cited in study report): SPP100 C6
- Substance type: White, fine-crystallic powder
- Physical state: Solid
- Stability under test conditions: Not indicated
- Storage condition of test material: Stored at ambient temperature
- Analytical purity: 99.2%
Significant impurities: Sum of all impurities by HPLC: 0.8%
Solvent content: Isopropyl acetate (CAS No. 108-21-4): 1.9% (w/w)
Methylcyclohexane (CAS 108-87-2): 5.8% (w/w)
- Lot/batch No.: HH-853.35Kr
- Expiration date of the lot/batch: December 2007

Study design

Oxygen conditions:
aerobic
Inoculum or test system:
other: Secondary effluent of the waste water treatment plant
Details on inoculum:
Source
- The source of test organisms was secondary effluent freshly obtained from a municipal sewage treatment plant: 'Pardbice, Czech, receiving predominantly domestic sewage.

Treatment
- Secondary effluent was filtered through a paper filter. COD was determined and the filtrate was kept aerated until inoculation.

Inoculation
- 2.1 ml filtrate of secondary effluent per litre of final volume.
Duration of test (contact time):
28 d
Initial test substance concentration
Initial conc.:
3.31 mg/L
Based on:
other: COD (Chemical oxygen demand)
Parameter followed for biodegradation estimation
Parameter followed for biodegradation estimation:
O2 consumption
Details on study design:
TEST CONDITIONS
- Composition of medium:
1 litre mineral medium contains: 1 ml of solution (A) to (D) and Milli-RO water
Stock solutions of mineral components
A) 8.50 g KH2PO4; 21.75 g K2HPO4; 33.40 g Na2HPO4.2H2O; 0.50 g NH4Cl; dissolved in Milli-Q water and made up to 1 litre, pH 7.4 ± 0.2
B) 22.50 g MgSO4.7H2O dissolved in Milli-Q water and made up to 1 litre.
C) 27.50 g CaCl2 dissolved in Milli-Q water and made up to 1 litre.
D) 0.25 g FeCl3.6H2O dissolved in Milli-Q water and made up to 1 litre.
- Test temperature: between 20 ± 1.0°C
- pH: At the start of the test: 7.4
- pH adjusted: no
- Continuous darkness: yes

TEST SYSTEM
- Culturing apparatus: approx. 280 ml BOD bottles with glass stoppers
- Number of culture flasks/concentration: 2 flasks per measuring point
- Test performed in open system: no

SAMPLING
- Sampling frequency: In duplicate; immediately at the start of the experiment (day 0), and on day 3, 7, 10, 14, 17, 21, 24 and 28
- Sampling method: Whole flask was used for measurement

CONTROL AND BLANK SYSTEM
- Inoculum blank: yes
- Procedure control: reference substance
- Toxicity control: yes, test substance, reference substance and inoculum
Reference substance
Reference substance:
other: sodium benzoate

Results and discussion

% Degradation
Parameter:
% degradation (O2 consumption)
Value:
11
Sampling time:
28 d

BOD5 / COD results

Results with reference substance:
The reference substance was degraded by at least 60% (85%) within 14 days .

Applicant's summary and conclusion

Validity criteria fulfilled:
yes
Interpretation of results:
under test conditions no biodegradation observed
Conclusions:
The test substance , SPP100 C6, is not ready biodegradble.