Registration Dossier

Data platform availability banner - registered substances factsheets

Please be aware that this old REACH registration data factsheet is no longer maintained; it remains frozen as of 19th May 2023.

The new ECHA CHEM database has been released by ECHA, and it now contains all REACH registration data. There are more details on the transition of ECHA's published data to ECHA CHEM here.

Diss Factsheets

Physical & Chemical properties

Auto flammability

Currently viewing:

Administrative data

Link to relevant study record(s)

Reference
Endpoint:
auto-flammability
Type of information:
experimental study
Adequacy of study:
key study
Study period:
Study Completion Date 05/11/2015
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
guideline study
Qualifier:
according to guideline
Guideline:
DIN 51794 (Testing of mineral oil hydrocarbons - Determination of ignition temperature)
Deviations:
no
Qualifier:
according to guideline
Guideline:
EU Method A.15 (Auto-Ignition Temperature (Liquids and Gases))
GLP compliance:
no
Specific details on test material used for the study:
Data of Test item as supplied by Huntsman Textile Effects
Identity: FAT 20036/G TE Lot. MH - 0033439900
Auto-ignition temperature:
> 550 °C
Atm. press.:
101.325 kPa
Conclusions:
No auto-ignition up to 550 °C was observed for FAT 20036/G TE.
Executive summary:

The determination of the auto-ignition temperature of the test item was performed in accordance with the EEC Directive Annex V of 67/548 Test A.15 auto-ignition temperature for liquids. In this study, the temperature of the oven and the sample were continuously recorded while the temperature of the oven was increased to approximately 550 °C at a rate of about 3- 5 °C/min. Then the test item is given drop by drop with pipette by cylinder hole into Erlenmeyer flask and observed for heat development. However, no auto-ignition was observed until 550 °C.

Description of key information

The determination of the auto-ignition temperature of the test item was performed in accordance with the EEC Directive Annex V of 67/548 Test A.15 auto-ignition temperature for liquids. In this study, the temperature of the oven and the sample were continuously recorded while the temperature of the oven was increased to approximately 550 °C at a rate of about 3- 5 °C/min. Then the test item is given drop by drop with pipette by cylinder hole into Erlenmeyer flask and observed for heat development. However, no auto-ignition was observed until 550 °C.

Key value for chemical safety assessment

Additional information