Registration Dossier

Data platform availability banner - registered substances factsheets

Please be aware that this old REACH registration data factsheet is no longer maintained; it remains frozen as of 19th May 2023.

The new ECHA CHEM database has been released by ECHA, and it now contains all REACH registration data. There are more details on the transition of ECHA's published data to ECHA CHEM here.

Diss Factsheets

Administrative data

Endpoint:
relative self-ignition temperature (solids)
Type of information:
experimental study
Adequacy of study:
key study
Study period:
1989, november 20th
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
other: GLP study performed according to the Test Guidelines described in the EEC Directive 84/449/EEC.

Data source

Reference
Reference Type:
study report
Title:
Unnamed
Year:
1989
Report date:
1989

Materials and methods

Test guideline
Qualifier:
according to guideline
Guideline:
EU Method A.16 (Relative Self-Ignition Temperature for Solids)
GLP compliance:
yes

Test material

Constituent 1
Chemical structure
Reference substance name:
3',5'-dichloro-4'-ethyl-2'-hydroxypalmitanilide
EC Number:
406-200-8
EC Name:
3',5'-dichloro-4'-ethyl-2'-hydroxypalmitanilide
Cas Number:
117827-06-2
Molecular formula:
C24H39Cl2NO2
IUPAC Name:
N-(3,5-dichloro-4-ethyl-2-hydroxyphenyl)hexadecanamide
Details on test material:
Identification UC—136
RCC Notox substance 1763
Description white powder
Batch Number Not indicated by the sponsor
Purity 98.5%
Storage conditions At room temperature in the dark in a tightly sealed container.
Stability of test substance Stable for one year maximal under storage condi ti ons
Expiry date: January 5, 1990
Safety precautions Gloves, goggles and face mask were used to assure personnel health and safety.

Results and discussion

Relative self-ignition temperature (solids)
Relative self-ignition temperature:
> 75 °C
Remarks on result:
other:
Remarks:
at atm. press. of 1.0 atm

Applicant's summary and conclusion

Conclusions:
No endothermic or exothermic reaction was observed between room
temperature and melting point of the test substance (58—60°C; as submitted
by the sponsor).
In conclusion, UC—136 is not auto—flammable under the test conditions.