Registration Dossier

Diss Factsheets

Physical & Chemical properties

Particle size distribution (Granulometry)

Currently viewing:

Administrative data

Link to relevant study record(s)

Reference
Endpoint:
particle size distribution (granulometry)
Type of information:
experimental study
Adequacy of study:
key study
Study period:
2016
Reliability:
2 (reliable with restrictions)
Qualifier:
according to guideline
Guideline:
OECD Guideline 110 (Particle Size Distribution / Fibre Length and Diameter Distributions - Method A: Particle Size Distribution (effective hydrodynamic radius)
Type of method:
Laser scattering/diffraction
Type of distribution:
volumetric distribution
Percentile:
D50
Mean:
ca. 45.012 µm
St. dev.:
0.932
No.:
#1
Size:
> 0 - <= 50 µm
Distribution:
56 %
No.:
#2
Size:
> 50 - <= 100 µm
Distribution:
31 %
No.:
#3
Size:
> 100 µm
Distribution:
13 %
Conclusions:
The mass median diameter is 45.012 μm.

Description of key information

The mass median diameter is 45.012 μm.

Additional information

None.