Registration Dossier

Data platform availability banner - registered substances factsheets

Please be aware that this old REACH registration data factsheet is no longer maintained; it remains frozen as of 19th May 2023.

The new ECHA CHEM database has been released by ECHA, and it now contains all REACH registration data. There are more details on the transition of ECHA's published data to ECHA CHEM here.

Diss Factsheets

Administrative data

Endpoint:
flash point of flammable liquids
Type of information:
experimental study
Adequacy of study:
key study
Study period:
23rd January 2014 - 27th January 2014
Reliability:
2 (reliable with restrictions)
Rationale for reliability incl. deficiencies:
comparable to guideline study with acceptable restrictions

Data source

Reference
Reference Type:
study report
Title:
Unnamed
Year:
2014
Report date:
2014

Materials and methods

Test guideline
Qualifier:
equivalent or similar to guideline
Guideline:
EU Method A.9 (Flash-Point)
GLP compliance:
yes (incl. QA statement)
Type of method:
closed cup
Flash point apparatus:
Setaflash apparatus

Test material

Constituent 1
Chemical structure
Reference substance name:
Reaction products of triethanolamine esters of polyphosphoric acids with alkyl derivatives of pyridine
EC Number:
939-981-3
IUPAC Name:
Reaction products of triethanolamine esters of polyphosphoric acids with alkyl derivatives of pyridine
Test material form:
liquid: viscous
Specific details on test material used for the study:
Date Prepared: 20 June 2013
Storage Conditions: Room temperature in the dark

Results and discussion

Flash pointopen allclose all
Flash point:
76 °C
Atm. press.:
98.1 kPa
Key result
Flash point:
74 °C
Atm. press.:
98.1 kPa

Any other information on results incl. tables

The flash point was corrected for atmospheric pressure using the following equation

Corrected flash point = C + 0.23 (101.325 – p)

Where:

C = observed flash point [°C]

P = ambient atmospheric pressure [kPa]

Applicant's summary and conclusion

Interpretation of results:
GHS criteria not met
Conclusions:
The test item has been determined to have a flash point of 74.7 ± 2 °C.
This does not meet the GHS criteria of a flammable liquid
Executive summary:

The test item has been determined to have a flash point of 74.7 ± 2 °C.