Registration Dossier

Data platform availability banner - registered substances factsheets

Please be aware that this old REACH registration data factsheet is no longer maintained; it remains frozen as of 19th May 2023.

The new ECHA CHEM database has been released by ECHA, and it now contains all REACH registration data. There are more details on the transition of ECHA's published data to ECHA CHEM here.

Diss Factsheets

Administrative data

Endpoint:
flash point of flammable liquids
Type of information:
experimental study
Adequacy of study:
key study
Reliability:
2 (reliable with restrictions)
Rationale for reliability incl. deficiencies:
comparable to guideline study with acceptable restrictions

Data source

Reference
Reference Type:
study report
Title:
Unnamed
Year:
2010
Report date:
2010

Materials and methods

Test guideline
Qualifier:
no guideline followed
Principles of method if other than guideline:
ASTM D7094 - Standard Test Method for Flash Point by Modified Continuously Closed Cup (MCCCFP) Tester
GLP compliance:
no
Type of method:
other: continuously closed cup flash point (CCCFP)

Test material

Constituent 1
Chemical structure
Reference substance name:
Reaction mass of 1,3-phenylenebis(propane-2,2-diylcarbamoyloxyethane-2,1-diyl) bis(2-methylacrylate) and 2-{[(2-{3-[2-({[2-(methacryloyloxy)ethoxy]carbonyl}amino)propan-2-yl]phenyl}propan-2-yl)carbamoyl]oxy}propyl methacrylate and 1,3-phenylenebis(propane-2,2-diylcarbamoyloxypropane-2,1-diyl) bis(2-methylacrylate)
Molecular formula:
C26H36N2O8, C27H38N2O8, C28H40N2O8
IUPAC Name:
Reaction mass of 1,3-phenylenebis(propane-2,2-diylcarbamoyloxyethane-2,1-diyl) bis(2-methylacrylate) and 2-{[(2-{3-[2-({[2-(methacryloyloxy)ethoxy]carbonyl}amino)propan-2-yl]phenyl}propan-2-yl)carbamoyl]oxy}propyl methacrylate and 1,3-phenylenebis(propane-2,2-diylcarbamoyloxypropane-2,1-diyl) bis(2-methylacrylate)

Results and discussion

Flash point
Key result
Flash point:
> 120 °C
Remarks on result:
other: No data available for atm. pressure

Applicant's summary and conclusion

Conclusions:
Flash point > 120°C
Executive summary:

The flash point of the test substance has been determined to be > 120 °C in a non-GLP test according to ASTM D7094.