Physical & Chemical properties

Particle size distribution (Granulometry)

Currently viewing:

Administrative data

Link to relevant study record(s)

Reference
Endpoint:
particle size distribution (granulometry)
Type of information:
experimental study
Adequacy of study:
key study
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
other: Experimental data
Qualifier:
according to guideline
Guideline:
other: as mentioned below
Principles of method if other than guideline:
The particle size distribution of test test chemical was determined by granulometric analysis with rotap sieve shaker
GLP compliance:
no
Type of method:
sieving
Type of distribution:
counted distribution
Percentile:
D50
Remarks on result:
other: Migrated from fields under 'Mass median diameter' as D50 percentile. No source field for Standard deviation.
No.:
#1
Size:
150 µm
Distribution:
3.02 %
Remarks on result:
other: No additional information available
No.:
#2
Size:
106 µm
Distribution:
4.2 %
Remarks on result:
other: No additional information available
No.:
#3
Size:
75 µm
Distribution:
26.69 %
Remarks on result:
other: No additional information available
No.:
#4
Size:
53 µm
Distribution:
41.15 %
Remarks on result:
other: No additional information available
No.:
#5
Size:
25 µm
Distribution:
24.9 %
Remarks on result:
other: No additional information available
No.:
#6
Size:
10 µm
Distribution:
0.02 %
Remarks on result:
other: No additional information available

Observation Table:

Amount of test item weighed (g) =5.002 g

Method run time (min) =10 min

Sieve sizes(in microns)

Weight of petridishes +

test item (g)

Test item quantity retained after sieving (g)

Percentage (%) of test item*

 150 microns

 44.565

0.135

3.02

 106 microns

44.822

0.188

4.20

75 microns 

 48.825

1.193

26.69

 53 microns

43.582

1.839

41.15

 25 microns

 45.727

 1.113

24.90

10 microns

37.373

0.001

0.02

 

Percentage of test item =   Test item retained on each sieve after sieving X 100

                                                   Original test itemtaken

 

Conclusions:
The particle size distribution of test test chemical was determined by granulometric analysis with rotap sieve shaker. The particle size distribution was observed to bein the range of 150 micron to 10 micron.
Executive summary:

The particle size distribution of test chemical was determined by granulometric analysis with rotap sieve shaker. The particle size distribution was observed to be in the range of 150 micron to 10 micron.

Description of key information

The particle size distribution of test chemical was determined by granulometric analysis with rotap sieve shaker.

The particle size distribution was observed to bein the range of 150 micron to 10 micron.

Additional information

The particle size distribution of test chemical was determined by granulometric analysis with rotap sieve shaker.

The particle size distribution was observed to bein the range of 150 micron to 10 micron.