Registration Dossier

Data platform availability banner - registered substances factsheets

Please be aware that this old REACH registration data factsheet is no longer maintained; it remains frozen as of 19th May 2023.

The new ECHA CHEM database has been released by ECHA, and it now contains all REACH registration data. There are more details on the transition of ECHA's published data to ECHA CHEM here.

Diss Factsheets

Environmental fate & pathways

Adsorption / desorption

Currently viewing:

Administrative data

Link to relevant study record(s)

Reference
Endpoint:
adsorption / desorption: screening
Type of information:
experimental study
Adequacy of study:
key study
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
guideline study
Justification for type of information:
Experimental test result performed using standard OECD test guidelines
Qualifier:
according to guideline
Guideline:
OECD Guideline 121 (Estimation of the Adsorption Coefficient (Koc) on Soil and on Sewage Sludge using High Performance Liquid Chromatography (HPLC))
GLP compliance:
no
Type of method:
HPLC estimation method
Media:
soil/sewage sludge
Radiolabelling:
no
Test temperature:
25°C
Details on study design: HPLC method:
HPLC Procedure:
The solutions of the test substance and reference substances were prepared in solvent mentioned in 4.3. Each of the reference substance and test substance were analysed by HPLC at 210 nm.
After equilibration of the HPLC system, Urea was injected first, the reference substances were injected in duplicate, followed by the test chemical solution in duplicate. Reference substances were injected again after test sample, no change in retention time of reference substances was observed. Retention time tR were measured, averaged and the decimal logarithms of the capacity factors k were calculated. The graph was plotted between log Koc versus log k(table 3).The linear regression parameter of the relationship log Koc vs log k were also calculated from the data obtained with calibration samples and therewith, log Koc of the test substance was determined from its measured capacity factor.

Operating Conditions:
HPLC Model No. : Agilent Technologies,1260 Infinity
Flow Rate : 1.0ml/min
Column : ZORBAX Eclipse Plus C18, 4.6×100mm, 3.5 μm
Mobile phase : ACN : water (55:45)
Temperature : 25°C
Detector : Diode Array Detector @210nm
Injector : Autosampler
Injector volume : 10μl
Data Acquisition software : ChemStationOpen lab Control Panel
Analytical monitoring:
no
Details on sampling:
- Concentrations: 500 mg/l
- Sampling interval: A test item solution was prepared by accurately weighing 5 mg of test item and diluted with acetonitrile up to 10 ml. Thus, the test solution concentration was 500 mg/l. The pH of test substance was 6.6.
Key result
Sample No.:
#1
Type:
log Koc
Value:
3.089 dimensionless
pH:
6.6
Temp.:
25 °C
Remarks on result:
other: logKoc was reported to be 3.089 ± 0.000
Details on results (HPLC method):
The Adsorption coefficient (KOC) on soil and on sewage sludge of the test chemical was determined to be 3.089 ± 0.000 at 25°C.
Transformation products:
not specified

Table 1:

Test substance

K

LogK

Log Koc

by Generalized Calibration

Graph

Mean of Log Koc ± S.D.

tR1

6.191

5.980

0.777

3.088

3.089 ± 0.000

tR2

6.196

5.985

0.777

3.089

Validity criteria fulfilled:
yes
Conclusions:
The Adsorption Coefficient of test chemical was determined as per the HPLC method (OECD Guideline-121). The Log Koc value was determined to be 3.089 ± 0.000 at 25°C.
Executive summary:

The adsorption coefficient Koc in soil and in sewage sludge of test chemical was determined by the Reverse Phase High Performance Liquid Chromatographic method according to OECD Guideline No. 121 for testing of Chemicals. The solutions of the test substance and reference substances were prepared in appropriate solvents. A test item solution was prepared by accurately weighing 5 mg of test item and diluted with acetonitrile up to 10 ml. Thus, the test solution concentration was 500 mg/l. The pH of test substance was 6.6. Each of the reference substance and test substance were analysed by HPLC at 210 nm. After equilibration of the HPLC system, Urea was injected first, the reference substances were injected in duplicate, followed by the test chemical solution in duplicate. Reference substances were injected again after test sample, no change in retention time of reference substances was observed. Retention time tR were measured, averaged and the decimal logarithms of the capacity factors k were calculated. The graph was plotted between log Koc versus log k. The linear regression parameter of the relationship log Koc vs log k were also calculated from the data obtained with calibration samples and therewith, log Koc of the test substance was determined from its measured capacity factor. The reference substances were chosen according to functional similarity with the test substance and calibration graph prepared. The reference substances were Benzamide, 4-chloroaniline, Aniline, 2,5-Dichloroaniline, Naphthalene, 1,2,3-trichlorobenzene, Phenanthrene having Koc value ranging from 1.26 to 4.09. The Log Koc value of test chemical was determined to be 3.089 ± 0.000 at 25°C. This log Koc value indicates that the test chemical has a moderate sorption to soil and sediment and therefore have slow migration potential to ground water.

Description of key information

The adsorption coefficient Koc in soil and in sewage sludge of test chemical was determined by the Reverse Phase High Performance Liquid Chromatographic method according to OECD Guideline No. 121 for testing of Chemicals. The solutions of the test substance and reference substances were prepared in appropriate solvents. A test item solution was prepared by accurately weighing 5 mg of test item and diluted with acetonitrile up to 10 ml. Thus, the test solution concentration was 500 mg/l. The pH of test substance was 6.6. Each of the reference substance and test substance were analysed by HPLC at 210 nm. After equilibration of the HPLC system, Urea was injected first, the reference substances were injected in duplicate, followed by the test chemical solution in duplicate. Reference substances were injected again after test sample, no change in retention time of reference substances was observed. Retention time tR were measured, averaged and the decimal logarithms of the capacity factors k were calculated. The graph was plotted between log Koc versus log k. The linear regression parameter of the relationship log Koc vs log k were also calculated from the data obtained with calibration samples and therewith, log Koc of the test substance was determined from its measured capacity factor. The reference substances were chosen according to functional similarity with the test substance and calibration graph prepared. The reference substances were Benzamide, 4-chloroaniline, Aniline, 2,5-Dichloroaniline, Naphthalene, 1,2,3-trichlorobenzene, Phenanthrene having Koc value ranging from 1.26 to 4.09. The Log Koc value of test chemical was determined to be 3.089 ± 0.000 at 25°C. This log Koc value indicates that the test chemical has a moderate sorption to soil and sediment and therefore have slow migration potential to ground water.

Key value for chemical safety assessment

Koc at 20 °C:
1 227.43

Additional information

The adsorption coefficient Koc in soil and in sewage sludge of test chemical was determined by the Reverse Phase High Performance Liquid Chromatographic method according to OECD Guideline No. 121 for testing of Chemicals. The solutions of the test substance and reference substances were prepared in appropriate solvents. A test item solution was prepared by accurately weighing 5 mg of test item and diluted with acetonitrile up to 10 ml. Thus, the test solution concentration was 500 mg/l. The pH of test substance was 6.6. Each of the reference substance and test substance were analysed by HPLC at 210 nm. After equilibration of the HPLC system, Urea was injected first, the reference substances were injected in duplicate, followed by the test chemical solution in duplicate. Reference substances were injected again after test sample, no change in retention time of reference substances was observed. Retention time tR were measured, averaged and the decimal logarithms of the capacity factors k were calculated. The graph was plotted between log Koc versus log k. The linear regression parameter of the relationship log Koc vs log k were also calculated from the data obtained with calibration samples and therewith, log Koc of the test substance was determined from its measured capacity factor. The reference substances were chosen according to functional similarity with the test substance and calibration graph prepared. The reference substances were Benzamide, 4-chloroaniline, Aniline, 2,5-Dichloroaniline, Naphthalene, 1,2,3-trichlorobenzene, Phenanthrene having Koc value ranging from 1.26 to 4.09. The Log Koc value of test chemical was determined to be 3.089 ± 0.000 at 25°C. This log Koc value indicates that the test chemical has a moderate sorption to soil and sediment and therefore have slow migration potential to ground water.