Registration Dossier

Diss Factsheets

Physical & Chemical properties

Flash point

Currently viewing:

Administrative data

Link to relevant study record(s)

Reference
Endpoint:
flash point of flammable liquids
Type of information:
experimental study
Adequacy of study:
key study
Study period:
2011-12-08
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
guideline study
Qualifier:
according to guideline
Guideline:
EU Method A.9 (Flash-Point)
Qualifier:
according to guideline
Guideline:
ASTM D93 (Standard test methods for flash point by pensky-martens closed cup tester)
GLP compliance:
no
Type of method:
closed cup
Flash point apparatus:
Pensky-Martens apparatus
Key result
Flash point:
131 °C
Atm. press.:
ca. 1 atm
Remarks on result:
other: The atmospheric pressure was reported as 'standard atmospheric pressure' without detailed value.
Interpretation of results:
GHS criteria not met
Conclusions:
Flash point: 131 °C
Executive summary:

In a guideline equivalent test, the flash point (closed cup method) of the test material was determined to be 131 °C.

Description of key information

Flash point: 131 °C

Key value for chemical safety assessment

Flash point at 101 325 Pa:
131 °C

Additional information

The flash point of test material has been determined to be 131 °C. According to CLP Regulation (EC) No 1272/2008 on classification, labelling and packaging of substances and mixtures, the liquid with flash point at 131 °C shall not be classified.