Registration Dossier

Data platform availability banner - registered substances factsheets

Please be aware that this old REACH registration data factsheet is no longer maintained; it remains frozen as of 19th May 2023.

The new ECHA CHEM database has been released by ECHA, and it now contains all REACH registration data. There are more details on the transition of ECHA's published data to ECHA CHEM here.

Diss Factsheets

Physical & Chemical properties

Particle size distribution (Granulometry)

Currently viewing:

Administrative data

Link to relevant study record(s)

Reference
Endpoint:
particle size distribution (granulometry)
Type of information:
experimental study
Adequacy of study:
key study
Study period:
05-11-2016 – 05-11-2016
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
comparable to guideline study
Justification for type of information:
Experimental test result performed using standard test guidelines
Qualifier:
according to guideline
Guideline:
other: granulometric analysis with rotap sieve shaker.
Principles of method if other than guideline:
The particle size distribution of test chemical 1-chloro-3-nitrobenzene was determined by Granulometric analysis with Rotap sieve shaker
GLP compliance:
no
Type of method:
sieving
Type of particle tested:
primary particle
Type of distribution:
counted distribution
Key result
Percentile:
D50
Remarks on result:
other: Mass median diameter
No.:
#1
Size:
150 µm
Distribution:
100 %
Remarks on result:
other: No other detail available

OBSERVATION TABLE:

Amount of sample weighed (g) = 10.050 g

Method run time (minutes) =10 min

Weight of empty container (g) =0.301 gm

Sieve sizes(in microns)

Weight of container + test substance (g)

Sample quantity retained after sieving (g)

Percentage (%) of sample*

150 microns

57.687 g

10.049 g

100%

106 microns

-

-

-

75 microns

-

-

-

53 microns

-

-

-

25 microns

-

-

-

10 microns

-

-

-

Conclusions:
The particle size distribution of test chemical 1-chloro-3-nitrobenzene was determined by Granulometric analysis with Rotap sieve shaker. The particle size distribution was determined to be150 micron.
Executive summary:

The particle size distribution of test chemical 1-chloro-3-nitrobenzene was determined by Granulometric analysis with Rotap sieve shaker. The particle size distribution was determined to be150 micron.

Description of key information

The particle size distribution of test chemical 1-chloro-3-nitrobenzene was determined by Granulometric analysis with Rotap sieve shaker. The particle size distribution was determined to be150 micron.

Additional information

The particle size distribution of test chemical 1-chloro-3-nitrobenzene was determined by Granulometric analysis with Rotap sieve shaker. The particle size distribution was determined to be150 micron.