Registration Dossier

Administrative data

Endpoint:
stability: thermal, sunlight, metals, other
Remarks:
Migrated from section 'Stability: thermal, sunlight, metals'
Type of information:
experimental study
Adequacy of study:
supporting study
Study period:
From Aug. 2, 1989 to Aug. 2, 1989
Reliability:
4 (not assignable)
Rationale for reliability incl. deficiencies:
other: Documentation insufficient for assessment.

Data source

Reference
Reference Type:
study report
Title:
Unnamed
Year:
1989
Report date:
1989

Materials and methods

Test guideline
Qualifier:
according to guideline
Guideline:
other: internal method
Deviations:
not specified
Principles of method if other than guideline:
Examination in a Lütolf-Oven in an open container (up to 250°C) and in a closed mini-autoclave (up to 350°C).
GLP compliance:
no

Test material

Reference
Name:
Unnamed
Type:
Constituent
Details on test material:
Name of test material (as cited in study report): CG 21-1201

Results and discussion

For thermal stability study

Test substance thermally stable:
yes
Operating temperature
Operating temp.:
<= 350 °C
Sublimation:
no
Transformation products:
no

For study on stability to sunlight

Test substance stable to sunlight:
not determined

For study on stability to metals

Test substance stable to metals / metal ions:
not determined

Applicant's summary and conclusion