Registration Dossier

Diss Factsheets

Physical & Chemical properties

Auto flammability

Currently viewing:

Administrative data

Link to relevant study record(s)

Reference
Endpoint:
relative self-ignition temperature (solids)
Type of information:
experimental study
Adequacy of study:
key study
Study period:
February - April 2016
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
guideline study
Qualifier:
according to guideline
Guideline:
EU Method A.16 (Relative Self-Ignition Temperature for Solids)
Deviations:
no
GLP compliance:
yes (incl. QA statement)
Specific details on test material used for the study:
SOURCE OF TEST MATERIAL
- Test Substance Name: LZ 514
- Source: Lonza Ltd, Visp/Switzerland
- Lot/batch No.of test material: 5011
- Expiration date of the lot/batch: 2nd December 2017
- Manufacture date: 3rd December 2015

STABILITY AND STORAGE CONDITIONS OF TEST MATERIAL
- Storage conditions: Controlled room temperature (15-25 ºC, below 70 RH%), protected from light and humidity.
- Stability under test conditions: stable
- Safety precautions: Routine safety precautions (lab coat, gloves, safety glasses, face mask) for unknown materials were applied to assure personnel health and safety.
Key result
Relative self-ignition temperature:
> 105 °C
Conclusions:
The relative self-ignition temperature was determined to be > 105°C at about 98.8 kPa atmospheric pressure.
Executive summary:

The test was conducted according to EU testing method A.16. The measured self-ignition temperature of the test item was > 105° at an atmospheric pressure of ca. 98.8 kPa.

Description of key information

The test was conducted according to EU testing method A.16. The measured self-ignition temperatures of the test item was > 105° at an atmospheric pressure of ca. 98.8 kPa.

Key value for chemical safety assessment

Autoflammability / Self-ignition temperature at 101 325 Pa:
105 °C

Additional information

Source: GLP-report