Registration Dossier

Diss Factsheets

Physical & Chemical properties

Density

Currently viewing:

Administrative data

Link to relevant study record(s)

Reference
Endpoint:
relative density
Type of information:
experimental study
Adequacy of study:
key study
Study period:
June - July 2016
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
guideline study
Qualifier:
according to guideline
Guideline:
EU Method A.3 (Relative Density)
Deviations:
no
Qualifier:
according to guideline
Guideline:
OECD Guideline 109 (Density of Liquids and Solids)
Deviations:
no
GLP compliance:
yes (incl. QA statement)
Type of method:
pycnometer method
Specific details on test material used for the study:
SOURCE OF TEST MATERIAL
- Test Substance Name: LZ 514
- Source: Lonza Ltd, Visp/Switzerland
- Lot/batch No.of test material: 5011
- Expiration date of the lot/batch: 2nd December 2017
- Manufacture date: 3rd December 2015

STABILITY AND STORAGE CONDITIONS OF TEST MATERIAL
- Storage conditions: Controlled room temperature (15-25 ºC, below 70 RH%), protected from light and humidity.
- Stability under test conditions: stable
- Safety precautions: Routine safety precautions (lab coat, gloves, safety glasses, face mask) for unknown materials were applied to assure personnel health and safety.
Key result
Type:
relative density
Density:
1.179
Temp.:
20 °C
Conclusions:
The relative density of the test item was determined to be 1.179.
Executive summary:

The study was performed according to OECD method 109, using the pycnometer method. The density was found to be 1.179 g/cm3 at 20°C.

Description of key information

The study was performed according to OECD method 109, using the pycnometer method. The density was found to be 1.179 g/cm3 at 20°C.

Key value for chemical safety assessment

Relative density at 20C:
1.179

Additional information

Source: GLP-report