Registration Dossier

Data platform availability banner - registered substances factsheets

Please be aware that this old REACH registration data factsheet is no longer maintained; it remains frozen as of 19th May 2023.

The new ECHA CHEM database has been released by ECHA, and it now contains all REACH registration data. There are more details on the transition of ECHA's published data to ECHA CHEM here.

Diss Factsheets

Physical & Chemical properties

Vapour pressure

Currently viewing:

Administrative data

Link to relevant study record(s)

Reference
Endpoint:
vapour pressure
Type of information:
experimental study
Adequacy of study:
key study
Study period:
24-Nov-2014
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
guideline study
Qualifier:
according to guideline
Guideline:
EU Method A.4 (Vapour Pressure)
Qualifier:
according to guideline
Guideline:
OECD Guideline 104 (Vapour Pressure Curve)
Qualifier:
according to guideline
Guideline:
EPA OPPTS 830.7950 (Vapor Pressure)
GLP compliance:
no
Type of method:
dynamic method
Remarks:
Vapour-liquid equilibrium
Key result
Temp.:
20 °C
Vapour pressure:
0.16 hPa
Key result
Temp.:
25 °C
Vapour pressure:
0.21 hPa
Key result
Temp.:
50 °C
Vapour pressure:
0.8 hPa

Dynamic method: Vapour-liquid equilibrium (VLE)

The vapour pressure was measured in the temperature range of 114.0 to 167.8 °C. The measured vapour pressure values together with the measured temperatures are given Table 1.

 

Table 1: Results of the dynamic method

No.

Temperature / °C

Vapour pressure / hPa

Remark

1

114.0

11.7

Measured up

2

133.9

19.7

Measured up

3

147.2

29.9

Measured up

4

155.6

39.9

Measured up

5

161.3

49.8

Measured up

6

167.8

59.5

Measured up

7

161.6

49.6

Measured down

8

146.8

29.9

Measured down

9

121.1

14.9

Measured down

 

From the measured data points of the vapour pressure curve of the constants A, B and C of the Antoine equation:

 

Log10 ρ = A +  B / C + θ

 

Can be derived by regression (Microsoft excel) of the data points

 

A = 8.8311

B = -2239.00

C = 273.15

 

Final results

The vapour pressure of the test item was calculated by extrapolation of the measured vapour pressure curve for the temperatures 20, 25 and 50 °C, according to Regulation EC 440/2008 Method A.4. Vapour Pressure.

 

Table 2: Calculated vapour pressure values for 20, 25 and 50 °C

           

Temperature / °C

Vapour pressure / hPa

20

0.16

25

0.21

50

0.80

     

Conclusions:
Vapour pressure values of 0.16 hPa (at 20 °C), 0.21 hPa (at 25 °C) and 0.8 hPa (at 50 °C) were determined for the test substance according to EU Method A.4.

Description of key information

Vapour pressure: 0.21 hPa at 25 °C (EU Method A.4, dynamic method)

Key value for chemical safety assessment

Vapour pressure:
0.21 hPa
at the temperature of:
25 °C

Additional information

Vapour pressure values of 0.16 hPa (at 20 °C), 0.21 hPa (at 25 °C) and 0.8 hPa (at 50 °C) were determined for the test substance according to EU Method A.4.