Registration Dossier

Diss Factsheets

Physical & Chemical properties

Auto flammability

Currently viewing:

Administrative data

Link to relevant study record(s)

Reference
Endpoint:
auto-ignition temperature (liquids)
Type of information:
experimental study
Adequacy of study:
key study
Study period:
21 September 2015
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
guideline study
Qualifier:
according to guideline
Guideline:
EU Method A.15 (Auto-Ignition Temperature (Liquids and Gases))
Deviations:
no
GLP compliance:
no
Specific details on test material used for the study:
SOURCE OF TEST MATERIAL
- Code number of the test material as used in the study report: FAT 93460/D
- Source and lot/batch No.of test material: Lot. 20140721(China)
Auto-ignition temperature:
> 550 °C
Atm. press.:
1 atm
Conclusions:
The auto-ignition temperature of the test item was determined to be >550 °C.
Executive summary:

The determination of the auto-ignition temperature of the test item was performed in accordance with the EU Method A.15. However, no auto-ignition was observed until 550 °C. Hence, the auto-ignition temperature of the test item was determined to be >550 °C.

Description of key information

The determination of the auto-ignition temperature of the test item was performed in accordance with the EU Method A.15. However, no auto-ignition was observed until 550 °C. Hence, the auto-ignition temperature of the test item was determined to be >550 °C.

Key value for chemical safety assessment

Autoflammability / Self-ignition temperature at 101 325 Pa:
550 °C

Additional information