Registration Dossier

Data platform availability banner - registered substances factsheets

Please be aware that this old REACH registration data factsheet is no longer maintained; it remains frozen as of 19th May 2023.

The new ECHA CHEM database has been released by ECHA, and it now contains all REACH registration data. There are more details on the transition of ECHA's published data to ECHA CHEM here.

Diss Factsheets

Administrative data

Endpoint:
flash point of flammable liquids
Type of information:
experimental study
Adequacy of study:
key study
Study period:
22/04/2015-06/05-2015
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
guideline study
Remarks:
in accordance with GLP

Data source

Reference
Reference Type:
study report
Title:
Unnamed
Year:
2015
Report date:
2015

Materials and methods

Test guidelineopen allclose all
Qualifier:
according to guideline
Guideline:
EU Method A.9 (Flash-Point)
Deviations:
no
Qualifier:
according to guideline
Guideline:
ISO 2719 (Determination of flash point - Pensky-Martens closed cup method)
Version / remarks:
2002
Deviations:
no
Qualifier:
according to guideline
Guideline:
ISO 3679 (Determination of flash point - Rapid equilibrium closed cup method)
Version / remarks:
2004
Deviations:
no
GLP compliance:
yes (incl. QA statement)
Type of method:
closed cup

Test material

Constituent 1
Reference substance name:
Cedrus atlantica, ext.
EC Number:
295-985-9
EC Name:
Cedrus atlantica, ext.
Cas Number:
92201-55-3
Molecular formula:
Not applicable due to UVCB nature of the substance
IUPAC Name:
Essential oil of Cedarwood Atlas obtained from the wood of Cedrus atlantica by steam distillation
Test material form:
liquid
Details on test material:
Name of test material as cited in study report: CEDAR ATLANTICA OIL

STABILITY AND STORAGE CONDITIONS OF TEST MATERIAL
- Storage condition of test material: at room temperature

Results and discussion

Flash point
Key result
Flash point:
112 °C
Atm. press.:
1 013 hPa
Remarks on result:
other: flash point automatically corrected to atmospheric pressure by instrument

Any other information on results incl. tables

Preliminary test

The estimated flash-point of the test substance was 111°C.

Main test

The results of the main study on the determination of the flash-point of the test substance are given in Table 1.

Table 1: Main study - flash-point of the test substance

Test

Flash-point

[°C]

1

112

2

112

Applicant's summary and conclusion

Interpretation of results:
GHS criteria not met
Conclusions:
The flash point of Cedarwood Atlas oil is 112°C at 1013 hPa.
Executive summary:

The flash point of Cedarwood Atlas oil was determined according to guidelines EC A.9, UN p. 32.4.1, ASTM D93, ASTM D7094, ISO 2719 and ISO 3679 using the closed-cup method with an Eraflash flash-point tester under GLP. The flash point was found to be 112°C at 1013 hPa.