Registration Dossier

Diss Factsheets

Physical & Chemical properties

Auto flammability

Currently viewing:

Administrative data

Link to relevant study record(s)

Reference
Endpoint:
auto-ignition temperature (liquids)
Type of information:
experimental study
Adequacy of study:
key study
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
comparable to guideline study
Justification for type of information:
Experimental test result performed using standard test guidelines
Qualifier:
according to guideline
Guideline:
other: Lowest temperature determined at which substance vaporizes to form an ignitable mixture in air
Principles of method if other than guideline:
Lowest temperature determined at which substance vaporizes to form an ignitable mixture in air
GLP compliance:
not specified
Other quality assurance:
other: not specified
Key result
Auto-ignition temperature:
27 °C
Atm. press.:
966 hPa
Remarks on result:
other: Test item did not catch fire on being exposed to air at room temperature of 27°C
Conclusions:
Test item did not catch fire on being exposed to air at room temperature of 27°C and atmospheric pressure of 966 hPa. This indicates that test item is not auto-flammable.
Executive summary:

Test item did not catch fire on being exposed to air at room temperature of 27°C and atmospheric pressure of 966 hPa. This indicates that test item is not auto-flammable.

Description of key information

Test item did not catch fire on being exposed to air at room temperature of 27°C and atmospheric pressure of 966 hPa. This indicates that test item is not auto-flammable.

Key value for chemical safety assessment

Additional information

Test item did not catch fire on being exposed to air at room temperature of 27°C and atmospheric pressure of 966 hPa. This indicates that test item is not auto-flammable.