Registration Dossier
Registration Dossier
Diss Factsheets
Use of this information is subject to copyright laws and may require the permission of the owner of the information, as described in the ECHA Legal Notice.
EC number: 617-084-5 | CAS number: 80474-45-9
- Life Cycle description
- Uses advised against
- Endpoint summary
- Appearance / physical state / colour
- Melting point / freezing point
- Boiling point
- Density
- Particle size distribution (Granulometry)
- Vapour pressure
- Partition coefficient
- Water solubility
- Solubility in organic solvents / fat solubility
- Surface tension
- Flash point
- Auto flammability
- Flammability
- Explosiveness
- Oxidising properties
- Oxidation reduction potential
- Stability in organic solvents and identity of relevant degradation products
- Storage stability and reactivity towards container material
- Stability: thermal, sunlight, metals
- pH
- Dissociation constant
- Viscosity
- Additional physico-chemical information
- Additional physico-chemical properties of nanomaterials
- Nanomaterial agglomeration / aggregation
- Nanomaterial crystalline phase
- Nanomaterial crystallite and grain size
- Nanomaterial aspect ratio / shape
- Nanomaterial specific surface area
- Nanomaterial Zeta potential
- Nanomaterial surface chemistry
- Nanomaterial dustiness
- Nanomaterial porosity
- Nanomaterial pour density
- Nanomaterial photocatalytic activity
- Nanomaterial radical formation potential
- Nanomaterial catalytic activity
- Endpoint summary
- Stability
- Biodegradation
- Bioaccumulation
- Transport and distribution
- Environmental data
- Additional information on environmental fate and behaviour
- Ecotoxicological Summary
- Aquatic toxicity
- Endpoint summary
- Short-term toxicity to fish
- Long-term toxicity to fish
- Short-term toxicity to aquatic invertebrates
- Long-term toxicity to aquatic invertebrates
- Toxicity to aquatic algae and cyanobacteria
- Toxicity to aquatic plants other than algae
- Toxicity to microorganisms
- Endocrine disrupter testing in aquatic vertebrates – in vivo
- Toxicity to other aquatic organisms
- Sediment toxicity
- Terrestrial toxicity
- Biological effects monitoring
- Biotransformation and kinetics
- Additional ecotoxological information
- Toxicological Summary
- Toxicokinetics, metabolism and distribution
- Acute Toxicity
- Irritation / corrosion
- Sensitisation
- Repeated dose toxicity
- Genetic toxicity
- Carcinogenicity
- Toxicity to reproduction
- Specific investigations
- Exposure related observations in humans
- Toxic effects on livestock and pets
- Additional toxicological data

Melting point / freezing point
Administrative data
Link to relevant study record(s)
- Endpoint:
- melting point/freezing point
- Type of information:
- experimental study
- Adequacy of study:
- key study
- Study period:
- 30th March 2015 - 30th March 2015
- Reliability:
- 1 (reliable without restriction)
- Rationale for reliability incl. deficiencies:
- guideline study
- Qualifier:
- according to guideline
- Guideline:
- EU Method A.1 (Melting / Freezing Temperature)
- Deviations:
- no
- GLP compliance:
- yes
- Type of method:
- capillary method
- Key result
- Melting / freezing pt.:
- > 151 - < 153 °C
- Atm. press.:
- ca. 1 Bar
- Decomposition:
- no
- Sublimation:
- no
- Conclusions:
- Result : 151 - 153°C (range)
- Executive summary:
The test is conducted to determine the temperature or temperature range of the phase transition from a solid to a liquid.
The dry substance is finely pulverised in a mortar and is put into a capillary tube, fused at one end, so that the filling level is approximately 3 mm after being tightly packed. The temperature of the apparatus is heated to about 15°C below the expected melting temperature, then the filled capillary tubes are inserted and testing is started, generally at a maximum rate of 1°C/min.
This method has an estimated accuracy of ± 0.5°C. The test is conducted in accordance with the procedure described in EU Regulation (EC) 440/2008, Annex Part A test A1.
Interpretation of results:
The mean of at least three measurements, which are in the range of the estimated accuracy, is reported as the melting temperature.
If the difference between the temperature at the beginning and at the final stage of melting is within the limits of the accuracy of the method, the temperature at the final stage of melting is taken as the melting temperature; otherwise the two temperatures are reported.
If the substance decomposes or sublimes before the melting temperature is reached, the temperature at which the effect is observed shall be reported.
Result : 151 - 153°C (range)
Reference
Interpretation of results:
The mean of at least three measurements, which are in the range of the estimated accuracy, is reported as the melting temperature.
If the difference between the temperature at the beginning and at the final stage of melting is within the limits of the accuracy of the method, the temperature at the final stage of melting is taken as the melting temperature; otherwise the two temperatures are reported.
If the substance decomposes or sublimes before the melting temperature is reached, the temperature at which the effect is observed shall be reported.
Run Number | 1 | 2 | 3 |
Mass of sample Used (g) | 0.006 | 0.01 | 0.006 |
Initial Melting Point (°C) | 150.5 | 151.1 | 150.8 |
Final Melting Point (°C) | 152.0 | 153.2 | 152.9 |
Result : 151 - 153°C (range)
Description of key information
The test is conducted to determine the temperature or temperature range of the phase transition from a solid to a liquid.
The dry substance is finely pulverised in a mortar and is put into a capillary tube, fused at one end, so that the filling level is approximately 3 mm after being tightly packed. The temperature of the apparatus is heated to about 15°C below the expected melting temperature, then the filled capillary tubes are inserted and testing is started, generally at a maximum rate of 1°C/min.
This method has an estimated accuracy of ± 0.5°C. The test is conducted in accordance with the procedure described in EU Regulation (EC) 440/2008, Annex Part A test A1.
Interpretation of results:
The mean of at least three measurements, which are in the range of the estimated accuracy, is reported as the melting temperature.
If the difference between the temperature at the beginning and at the final stage of melting is within the limits of the accuracy of the method, the temperature at the final stage of melting is taken as the melting temperature; otherwise the two temperatures are reported.
If the substance decomposes or sublimes before the melting temperature is reached, the temperature at which the effect is observed shall be reported.
Result : 151 - 153°C (range)
Key value for chemical safety assessment
Additional information
Result : 151 - 153°C (range)
Information on Registered Substances comes from registration dossiers which have been assigned a registration number. The assignment of a registration number does however not guarantee that the information in the dossier is correct or that the dossier is compliant with Regulation (EC) No 1907/2006 (the REACH Regulation). This information has not been reviewed or verified by the Agency or any other authority. The content is subject to change without prior notice.