Registration Dossier
Registration Dossier
Diss Factsheets
Use of this information is subject to copyright laws and may require the permission of the owner of the information, as described in the ECHA Legal Notice.
EC number: 611-901-9 | CAS number: 5984-56-5
- Life Cycle description
- Uses advised against
- Endpoint summary
- Appearance / physical state / colour
- Melting point / freezing point
- Boiling point
- Density
- Particle size distribution (Granulometry)
- Vapour pressure
- Partition coefficient
- Water solubility
- Solubility in organic solvents / fat solubility
- Surface tension
- Flash point
- Auto flammability
- Flammability
- Explosiveness
- Oxidising properties
- Oxidation reduction potential
- Stability in organic solvents and identity of relevant degradation products
- Storage stability and reactivity towards container material
- Stability: thermal, sunlight, metals
- pH
- Dissociation constant
- Viscosity
- Additional physico-chemical information
- Additional physico-chemical properties of nanomaterials
- Nanomaterial agglomeration / aggregation
- Nanomaterial crystalline phase
- Nanomaterial crystallite and grain size
- Nanomaterial aspect ratio / shape
- Nanomaterial specific surface area
- Nanomaterial Zeta potential
- Nanomaterial surface chemistry
- Nanomaterial dustiness
- Nanomaterial porosity
- Nanomaterial pour density
- Nanomaterial photocatalytic activity
- Nanomaterial radical formation potential
- Nanomaterial catalytic activity
- Endpoint summary
- Stability
- Biodegradation
- Bioaccumulation
- Transport and distribution
- Environmental data
- Additional information on environmental fate and behaviour
- Ecotoxicological Summary
- Aquatic toxicity
- Endpoint summary
- Short-term toxicity to fish
- Long-term toxicity to fish
- Short-term toxicity to aquatic invertebrates
- Long-term toxicity to aquatic invertebrates
- Toxicity to aquatic algae and cyanobacteria
- Toxicity to aquatic plants other than algae
- Toxicity to microorganisms
- Endocrine disrupter testing in aquatic vertebrates – in vivo
- Toxicity to other aquatic organisms
- Sediment toxicity
- Terrestrial toxicity
- Biological effects monitoring
- Biotransformation and kinetics
- Additional ecotoxological information
- Toxicological Summary
- Toxicokinetics, metabolism and distribution
- Acute Toxicity
- Irritation / corrosion
- Sensitisation
- Repeated dose toxicity
- Genetic toxicity
- Carcinogenicity
- Toxicity to reproduction
- Specific investigations
- Exposure related observations in humans
- Toxic effects on livestock and pets
- Additional toxicological data

Partition coefficient
Administrative data
- Endpoint:
- partition coefficient
- Type of information:
- experimental study
- Adequacy of study:
- key study
- Study period:
- 26 August - 22 December 2015
- Reliability:
- 1 (reliable without restriction)
- Rationale for reliability incl. deficiencies:
- guideline study
Data source
Reference
- Reference Type:
- study report
- Title:
- Unnamed
- Year:
- 2 016
- Report date:
- 2016
Materials and methods
Test guidelineopen allclose all
- Qualifier:
- according to guideline
- Guideline:
- OECD Guideline 107 (Partition Coefficient (n-octanol / water), Shake Flask Method)
- Deviations:
- no
- Qualifier:
- according to guideline
- Guideline:
- EU Method A.8 (Partition Coefficient)
- Deviations:
- no
- Qualifier:
- according to guideline
- Guideline:
- EPA OPPTS 830.7550 (Partition Coefficient, n-octanol / H2O, Shake Flask Method)
- Deviations:
- no
- GLP compliance:
- yes
- Type of method:
- flask method
- Partition coefficient type:
- octanol-water
Test material
- Reference substance name:
- 4-piperidinecarboxylic acid hydrochloride
- EC Number:
- 611-901-9
- Cas Number:
- 5984-56-5
- Molecular formula:
- C6H11NO2.HCl
- IUPAC Name:
- 4-piperidinecarboxylic acid hydrochloride
- Test material form:
- solid: particulate/powder
- Details on test material:
- - Name of test material (as cited in study reports): JNJ-150098-AAC (T001310)
- Physical state: solid
- Appearance white powder
Constituent 1
- Specific details on test material used for the study:
- - Batch n°: I14KB4913
- Analytical purity: 97.4% (base titration)
- Expiration date: 23 November 2020 (retest date)
- Storage condition: at room temperature
Study design
- Analytical method:
- high-performance liquid chromatography
Results and discussion
Partition coefficient
- Key result
- Type:
- log Pow
- Partition coefficient:
- -3.2
- Temp.:
- 20 °C
- pH:
- 7
- Details on results:
- Preliminary test
The content of test item dissolved in the n-octanol sample was in the range of 0.1-0.3 g/L. In the chromatograms, two peaks were observed. One at 3.1 minutes which was used as response for the test item and a second peak at 2.25 minutes of which the origin is unknown. This peak at 2.25 minutes was not observed in chromatograms obtained during the main study.
Main study
In the blanks, no test item was measured in the aqueous phase. In the n-octanol phase, the concentration was calculated by extrapolation to be 6.1E-6 g/L in a first sample and 6.7E-6 g/L in a second sample.
The analysed concentration of the stock solution was 0.232 g/L. Based on this, the nominal quantity of the test item in the test samples was 0.465 mg. The recoveries were determined according to this value. Two values were unexpectedly high (i.e. 952% and 151%) and therefore not used for further calculation of the mean Pow and log Pow of the test item. The remaining log Pow values were within the criterion range of ± 0.3 log units.
Detailed results are given in the table in the field 'Any other information on results incl. tables'. The relatively large spread observed is due to the nature of the test item and cannot be prevented. Improvement of the method is not considered possible.
Any other information on results incl. tables
Ratio n-octanol:water (v:v) | Analysed concentration
|
Pow | Pow (mean) | log Pow | pH | ||||
1:1 | 9.59E-5 | 0.0848 | 1.1E-3 | 1.1E-3 | -2.9 | 7.1 | |||
1:1 | 3.71E-5 | 0.737 | 5.0E-5* | -4.3* | 7.1 | ||||
1:2 | 4.57E-5 | 0.0581 | 7.9E-4 | 6.4E-4 | -3.1 | 7.1 | |||
1:2 | 2.77E-5 | 0.0562 | 4.9E-4 | -3.3 | 7.1 | ||||
2:1 | 5.76E-5 | 0.175 | 3.3E-4* | 4.1E-4 | -3.5* | 7.0 | |||
2:1 | 4.82E-5 | 0.119 | 4.1E-4 | -3.4 | 7.1 | ||||
Mean | 5.6E-4 | -3.2 | |||||||
Standard deviation | 3.3E-4 |
*Not used for further calculation since recovery was unexpectedly high.
Recovery was between 97 and 110% (excluding two values (952% and 151%)).
Applicant's summary and conclusion
- Conclusions:
- The shake flask method at pH 7 was applied for the determination of the partition coefficient (Pow) of JNJ-150098-AAC (T001310).
The Pow value of the test item at 20°C was 5.6E-4. This corresponds to a log Pow value of -3.2.
Information on Registered Substances comes from registration dossiers which have been assigned a registration number. The assignment of a registration number does however not guarantee that the information in the dossier is correct or that the dossier is compliant with Regulation (EC) No 1907/2006 (the REACH Regulation). This information has not been reviewed or verified by the Agency or any other authority. The content is subject to change without prior notice.