Registration Dossier

Diss Factsheets

Administrative data

Endpoint:
auto-ignition temperature (liquids)
Type of information:
experimental study
Adequacy of study:
key study
Study period:
March 2014 - October 2016
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
guideline study

Data source

Reference
Reference Type:
study report
Title:
Unnamed
Year:
2016

Materials and methods

Test guidelineopen allclose all
Qualifier:
according to guideline
Guideline:
EU Method A.15 (Auto-Ignition Temperature (Liquids and Gases))
Deviations:
no
Qualifier:
according to guideline
Guideline:
DIN 51794 (Testing of mineral oil hydrocarbons - Determination of ignition temperature)
Deviations:
no
GLP compliance:
yes (incl. QA statement)

Test material

Constituent 1
Chemical structure
Reference substance name:
[1aR-(1aα,4aα,7α,8aS*)]-octahydro-4,4,8,8-tetramethyl-4a,7-methano-4aH-naphth[1,8a-b]oxirene
EC Number:
247-851-6
EC Name:
[1aR-(1aα,4aα,7α,8aS*)]-octahydro-4,4,8,8-tetramethyl-4a,7-methano-4aH-naphth[1,8a-b]oxirene
Cas Number:
26619-69-2
Molecular formula:
C15H24O
IUPAC Name:
[1aR-(1aα,4aα,7α,8aS*)]-octahydro-4,4,8,8-tetramethyl-4a,7-methano-4aH-naphth[1,8a-b]oxirene
impurity 1
Chemical structure
Reference substance name:
7,7,8,8-tetramethyloctahydro-2,3b-methanocyclopenta[1,3]cyclopropa[1,2]benzen-4-ol
Cas Number:
29461-20-9
Molecular formula:
C15H24O
IUPAC Name:
7,7,8,8-tetramethyloctahydro-2,3b-methanocyclopenta[1,3]cyclopropa[1,2]benzen-4-ol
Test material form:
liquid
Details on test material:
- Name of test material (as cited in the expert statement): Folenox
- Chemical name: 4,4,8,8-Tetramethyloctahydro-4a,7-methanonaphtho[1,8a-b]oxirene (IUPAC)
- Empirical formula: C15H24O
- Structural formula: See IUCLID section 1

Results and discussion

Auto-ignition temperature (liquids / gases)
Key result
Auto-ignition temperature:
260 °C
Atm. press.:
1 015 hPa

Applicant's summary and conclusion

Executive summary:

The results of the main study on the determination of the auto-ignition temperature of the test substance are given in Table 13.

Ignition of the test substance within 5 minutes after introduction was observed with each sample volume and with each test a minimum auto-ignition temperature was obtained. The maximum deviation between the three values was <10oC. According to the guidelines, no further testing was required. The lowest temperature at which ignition of the test substance occurred was 263°C. This temperature was rounded down to the nearest multiple of 5°C giving an auto-ignition temperature of the test substance of 260°C.