Registration Dossier

Diss Factsheets

Administrative data

Link to relevant study record(s)

Reference
Endpoint:
flammable solids
Type of information:
experimental study
Adequacy of study:
key study
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
guideline study
Qualifier:
according to guideline
Guideline:
EU Method A.10 (Flammability (Solids))
GLP compliance:
no
Key result
Test procedure:
ignition time on contact with air
Remarks:
Ignition on contact with air refers to either Pyrophoric solids or Pyrophoric liquids depending on physical state (migrated information).
Remarks on result:
no ignition on contact with air (not further specified)
Remarks:
corresponding to 'no' in migrated source record.
Key result
Test procedure:
ignition time on contact with air
Remarks:
Ignition on contact with air refers to either Pyrophoric solids or Pyrophoric liquids depending on physical state (migrated information).
Remarks on result:
no ignition on contact with air (not further specified)
Remarks:
corresponding to 'no' in migrated source record.
Key result
Remarks on result:
no reaction with water observed
Remarks:
corresponding to 'no' in migrated source record.

The test item is not highly flammable solid in the sense of the European Commission Regulation (EC) No. 440/2008, Method A.10. The test item could not be ignited with a flame. The test item melted.

Description of key information

The test item is not highly flammable solid in the sense of the European Commission Regulation (EC) No. 440/2008, Method A.10. The test item could not be ignited with a flame. The test item melted. 

Key value for chemical safety assessment

Additional information

The test item could not be ignited with a flame. The test item melted. The performance of the main test was not necessary.

Justification for classification or non-classification

The test item is not a highly flammable solid in the sense of the European Commission Regulation (EC) No. 440/2008, Method A.10.