Registration Dossier

Diss Factsheets

Physical & Chemical properties

Viscosity

Currently viewing:

Administrative data

Link to relevant study record(s)

Reference
Endpoint:
viscosity
Type of information:
experimental study
Adequacy of study:
key study
Study period:
2010
Reliability:
2 (reliable with restrictions)
Rationale for reliability incl. deficiencies:
other: Acceptable, well-documented study report which meets basic scientific principles, no GLP lab.
Qualifier:
according to guideline
Guideline:
other: ASTM D 7042
GLP compliance:
no
Remarks:
Non GLP certified lab
Type of method:
capillary viscometer (static)
Key result
Temp.:
20°C
Parameter:
kinematic viscosity (in mm²/s)
Value:
1.77
Conclusions:
The measured viscosity was 1.77 mm2/s at 20°C using test method ASTM D 7042.
Executive summary:

The measured viscosity was 1.77 mm2/s at 20°C using test method ASTM D 7042.

Description of key information

The viscosity at 20 deg C is 1.3 to 2.5 mm2/s according to the ASTM D 7042 testing methodology. 

Key value for chemical safety assessment

Additional information